Conversion Instructions (Model LPR1115AD*)
All ranges are equipped with fixed orifices and with a convertible appliance pressure regulator. The unit model number plate states which gas it was adjusted for at the factory. To convert the unit to either Natural gas or LP gas will require the replacement of orifice hoods, adjustment of the air shutters on the burners and adjustment of the appliance pressure regulator converter cap.
Inlet pressure to the appliance pressure regulator should be as follows for both operation and checking of appliance pressure regulator setting:
1.Shut off gas supply to appliance.
2.Disconnect electrical supply to appliance, if equipped.
3.Disconnect gas supply tubing to appliance.
4.Slide range forward to disengage range from the
5.Reverse procedure to reinstall. If gas line has been disconnected, check for gas leaks after reconnection.
A qualified servicer should disconnect and reconnect the gas supply.
The servicer follow installation instructions
provided with the gas appliance connector and the warning label attached to the connector.
Minimum | 5 | 11 |
Maximum | 14 | 14 |
6.To prevent range from accidentally tipping, range must be secured to the floor by sliding rear leveling leg into the
When your range requires service or replacement parts, contact your dealer or authorized service agency. Please give the complete model and serial numbers of the range which is located on the range model number plate.
16023522 | ©2004 Maytag Services |