Conversion Instructions (Model CPR1100AD*)
Range Adjustments
Top Section - Gas Top Pilot Adjustment
See figure 5.
Purge all air from supply system by turning on one top burner valve. Then turn off valve and adjust top pilot flame using adjusting screw “A” (figure 5) so that flame is even with top of flash tube. To light the burner, push and turn top burner knob to the lite position.
TOP OF FLASH TUBE
FIGURE 5
Top Section - Electric Ignition
To operate, push and turn burner knob to the LITE position. The top burner will light. To turn OFF spark after the top burner has ignited turn knob to HI setting.
Top Burner Adjustment
All Top Burner Valves:
The approximate height of the flame at the high or
6)to the widest opening that will not cause the flame to lift or blow off the burner when cold.
AIR
SHUTTER
3/4 FLAME
ORIFICE
HOOD
Conventional Burners
FIGURE 6
Air Shutter - Oven Burner
a. The approximate length of the flame of oven burner is a 1/2 distinct inner blue flame (see figure 7).
b. Oven burner flame can be checked as follows:
1.Yellow flame on burner - open air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold. (See figure 8).
2.Distinct blue flame but lifting - close burner air shutter to the point where it will not cause the flame to lift or blow off the burner when cold. (See figure 8).
1/2 FLAME INNER CONE
FIGURE 7
c.The oven burner air shutter adjustment is the same on ranges with a gas pilot or electric ignition.
LOCK SCREW
AIR SHUTTER
ORIFICE HOOD
FIGURE 8