Maytag CGR1110ADQ/W, CPL1100ADH/L/Q/T/W, AGR5712ADB/Q/S/W Surface Burner Conversion Conventional

Page 62

Conversion Instructions (Models AGR4400AD*, AGR4412AD*, MGR4451AD*, MGR4452AD*, PGR4420LD*, CGR1425AD*, CGR1415AD*, CGR1110AD*, CP31600AD*)

5.Place the corresponding orifice hood on the burner fitting according to figure 4. Turn the orifice hood clockwise by hand approximately one turn. Tighten the orifice hood clockwise with a ½￿ socket wrench approximately 2½ turns.

6.Replace the burner assembly in the main top and rotate one-eighth turn clockwise using the burner wrench until the burner locks in place with the igniter aligned with the reference mark on the main top.

7.Repeat steps 3 through 6 until all orifice hoods have been changed.

LP GAS SURFACE BURNER ORIFICE CONFIGURATION

6.5K BLUE

8K NO COLOR

STAMPED .0310

STAMPED .0335

 

ART. #9215-250-2

8K NO COLOR

8.5K RED

STAMPED .0335

STAMPED .0350

 

FRONT OF RANGE

NATURAL GAS SURFACE BURNER ORIFICE CONFIGURATION

7.2K BLUE

9.2K NO COLOR

STAMPED .0512

STAMPED .0571

 

ART. #9215-250-2

To Reassemble:

Replace burner assembly in main top and rotate approximately one-eighth turn clockwise using burner wrench until burner locks into position with ignitor aligned with reference mark on main top.

ORIFICE HOOD

FIGURE 5

Surface Burner Conversion (Conventional

Burner)

1.Remove main top.

2.Remove all (4) surface burners.

3.Remove all (4) orifice hoods (figure 6) from the valve by using a 1/2 wrench or socket and turning the hood counter-clockwise.

ORIFICE - Nat.: Stamped .0571

LP: Stamped .0335

FIGURE 6

NOTE: Save all parts removed in conversion.

4.Replace with the hoods stamped .0335 for LP (.0571 for natural) by using a 1/2 inch wrench or socket and turning the hood clockwise approximately (6) complete turns.

5.Replace surface burners.

9.2K NO COLOR

 

12K RED

STAMPED .0571

FRONT OF RANGE

STAMPED .0669

 

 

FIGURE 4

C–14

16023522

©2004 Maytag Services

Image 62
Contents Service Customer Service Support Center Important InformationTable of Contents Safety Practices for Servicer ServicingUsing the Oven Receiving OvenBaking, Broiling, and Roasting Connecting Range to GasProduct Safety Devices Electrical RequirementsGeneral Information Service SpecificationsPlacement of the Oven Parts and AccessoriesArning GroundingRange Description Troubleshooting Procedures Problem Possible Cause Correction Oven light does not operate Component Testing Procedures Spark module Test for voltage at terminals 120 VAC Seconds of powering up the unit Quick Test Mode for Electronic Range Control Sensor resistance Infinite Ohms Bake flashes Typical M1 Control Top Surface Valve and Spark Switch Maintop AssemblyRocker Switch Control Board AssemblyOpen Burner Valve / Regulator AssemblyManual Oven Door Latch Assembly Oven SensorBackguard Oven Door Hinge ReceiverSide Panel Removal Storage Drawer RemovalPower Cord Oven Light AssemblyFrameless Door Disassembly Large and Standard Windows Frameless Oven Door Large WindowDoor Disassembly No Window Oven Door No WindowAppendix a Installation Instructions Models CP31200AD*, CG31200AD 200 BTU/HR or Less Inches Installation Drawings Installation Drawings Installation Instructions Model LPR1115AD 200 BTU/HR or Less Inches 16023522 200 BTU/HR or Less Inches Appliance Pressure Regulator Alternate Connectors Flame 16023522 Appendix B Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Surface Cooking Oven Cooking Self-Clean Oven Control select models Pilotless Ignition E F To change the clock to Hour format Care & Cleaning Do not USE ANY Cleaning Product Containing Chlorine Bleach Appendix C Conversion Instructions Models CP31200AD*, CG31200AD Conversion Instructions Models CP31200AD*, CG31200AD GAS Conversion Gas Conversion Orifice Conversion Range Adjustments Conversion Instructions Model LPR1115AD 03-04-00 16023522 Orifice Hood Gas Conversion Orifice Conversion Surface Burner Conversion Conventional Air Shutter