Conversion Instructions (Models AGR4400AD*, AGR4412AD*, MGR4451AD*, MGR4452AD*, PGR4420LD*, CGR1425AD*, CGR1415AD*, CGR1110AD*, CP31600AD*)
5.Place the corresponding orifice hood on the burner fitting according to figure 4. Turn the orifice hood clockwise by hand approximately one turn. Tighten the orifice hood clockwise with a ½ socket wrench approximately 2½ turns.
6.Replace the burner assembly in the main top and rotate
7.Repeat steps 3 through 6 until all orifice hoods have been changed.
LP GAS SURFACE BURNER ORIFICE CONFIGURATION
6.5K BLUE | 8K NO COLOR |
STAMPED .0310 | STAMPED .0335 |
| ART. |
8K NO COLOR | 8.5K RED |
STAMPED .0335 | STAMPED .0350 |
| FRONT OF RANGE |
NATURAL GAS SURFACE BURNER ORIFICE CONFIGURATION
7.2K BLUE | 9.2K NO COLOR |
STAMPED .0512 | STAMPED .0571 |
| ART. |
To Reassemble:
Replace burner assembly in main top and rotate approximately
ORIFICE HOOD
FIGURE 5
Surface Burner Conversion (Conventional
Burner)
1.Remove main top.
2.Remove all (4) surface burners.
3.Remove all (4) orifice hoods (figure 6) from the valve by using a 1/2 wrench or socket and turning the hood
ORIFICE - Nat.: Stamped .0571
LP: Stamped .0335
FIGURE 6
NOTE: Save all parts removed in conversion.
4.Replace with the hoods stamped .0335 for LP (.0571 for natural) by using a 1/2 inch wrench or socket and turning the hood clockwise approximately (6) complete turns.
5.Replace surface burners.
9.2K NO COLOR |
| 12K RED |
STAMPED .0571 | FRONT OF RANGE | STAMPED .0669 |
|
|
FIGURE 4
16023522 | ©2004 Maytag Services |