Installation Instructions (All models except CPL1100AD*, CGL1100AD*, CP31200AD*, CG31200AD*, LPR1115AD*)
" #$ !
WHEN THE INSTALLER HAS COMPLETED INSTALLATION OF THE APPLIANCE, LEAVE THE APPLIANCE PRESSURE
REGULATOR |
| POSITION. |
!
Appliance Pressure Regulator
& Alternate Connectors
The appliance pressure regulator on your range may differ from this illustration.
h.Apply a
i.Remove shipping screw from ALL top burners. (Conventional top burner models only). This is to hold the burners in place on the burner bracket for shipping purposes only. (See figure 5).
j.Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold.
Correctly adjusted sealed burners, can have flames that will lift or blow off without a pot over the burner. These should be adjusted with a pot in place.
3.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 lbs./sq. in. (3.5 kPa) (13.8 in. water column).
4.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 lbs./sq. in. (3.5 kPa) (13.8 in. water column).
©2004 Maytag Services | 16023522 | A– 10 |