Maytag CG31600ADB/Q/V, CPL1100ADH/L/Q/T/W, AGR5712ADB/Q/S/W, CPL1110ADH/L/T, AGR4400ADW 03-04-00

Page 57

Conversion Instructions (Models AGR5712AD*, CG34800AD*, CGR3725AD*, MGR5751AD*, MGR5752AD*, PGR5720LD*)

All ranges are equipped with fixed orifices and with a convertible appliance pressure regulator. The unit model number plate states which gas it is adjusted for at the factory. To convert the unit to either Natural gas or LP gas will require the replacement of the orifice hoods, and the adjustment of the air shutters on the burners and adjustment of the appliance pressure regulator converter cap.

Inlet pressure to the appliance pressure regulator should be as follows for checking the appliance pressure regulator setting:

Reinstall cap nut to appliance pressure regulator and replace dust cover.

Be sure marking for the type of gas to which appliance pressure regulator has just been converted is visible in top of cap nut before replacing plastic dust cover. (See figure 1.)

Minimum

5

11

Maximum

14

14

The unit appliance pressure regulator must be set to match the type gas supply used. If converting from natural gas to LP gas, the appliance pressure regulator must be converted to regulate LP gas. If converting from LP gas to natural gas, the appliance pressure regulator must be converted to regulate natural gas.

To access the regulator from front of range, remove the storage drawer or warming drawer.

Pull out to the first stop

position. Lift up front of drawer and pull to the second position, grasp sides and lift up and out to remove drawer.

To convert the appliance pressure regulator from one gas to another, remove plastic dust cover from cap nut on top of appliance pressure regulator. Remove cap nut from appliance pressure regulator (plastic dust cover comes off with nut).

Remove plastic dust cover from cap nut

and reinstall on opposite side of cap nut.

Fit the drawer rollers onto the rails. Lift up drawer front and gently push in to first stop position. Lift up and continue to slide drawer to the closed position.

(03-04-00)

©2004 Maytag Services

16023522

C–9

Image 57
Contents Service Important Information Customer Service Support CenterTable of Contents Servicing Safety Practices for ServicerReceiving Oven Using the OvenProduct Safety Devices Connecting Range to GasBaking, Broiling, and Roasting Electrical RequirementsGeneral Information Placement of the Oven SpecificationsService Parts and AccessoriesGrounding ArningRange Description Troubleshooting Procedures Problem Possible Cause Correction Oven light does not operate Component Testing Procedures Spark module Test for voltage at terminals 120 VAC Seconds of powering up the unit Quick Test Mode for Electronic Range Control Sensor resistance Infinite Ohms Bake flashes Typical M1 Control Rocker Switch Maintop AssemblyTop Surface Valve and Spark Switch Control Board AssemblyManual Oven Door Latch Assembly Valve / Regulator AssemblyOpen Burner Oven SensorSide Panel Removal Oven Door Hinge ReceiverBackguard Storage Drawer RemovalOven Light Assembly Frameless Door Disassembly Large and Standard WindowsPower Cord Large Window Frameless Oven DoorOven Door No Window Door Disassembly No WindowAppendix a Installation Instructions Models CP31200AD*, CG31200AD 200 BTU/HR or Less Inches Installation Drawings Installation Drawings Installation Instructions Model LPR1115AD 200 BTU/HR or Less Inches 16023522 200 BTU/HR or Less Inches Appliance Pressure Regulator Alternate Connectors Flame 16023522 Appendix B Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Surface Cooking Oven Cooking Self-Clean Oven Control select models Pilotless Ignition E F To change the clock to Hour format Care & Cleaning Do not USE ANY Cleaning Product Containing Chlorine Bleach Appendix C Conversion Instructions Models CP31200AD*, CG31200AD Conversion Instructions Models CP31200AD*, CG31200AD GAS Conversion Gas Conversion Orifice Conversion Range Adjustments Conversion Instructions Model LPR1115AD 03-04-00 16023522 Orifice Hood Gas Conversion Orifice Conversion Surface Burner Conversion Conventional Air Shutter