Component Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

"Quick Test" Mode for Electronic Range Control

Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the control will exit the quick test mode.

1.Press and hold Cancel and Broil pads for 3 seconds.

2.Once the control has entered the "Quick Test" mode, release both pads.

3.Press each of the following pads indicated in the table below.

NOTE: First time one of following pads are pressed it will activate the response.

The second time the pad is pressed it will deactivate the response.

NOTE: This mode can only be entered within the first 5 minutes after power up.

NOTE: If the temperature sensor is greater than 400° F and the "Quick Test" mode will be disabled if the temperature sensor reaches 400° F while under test.

Display will indicate the following:

Key

Operation

[Bake]

Bake relay activated

[Broil]

Broil relay activated

[Keep Warm]

N\A

[Cook&Hold]

Last Diagnostic Code displayed

[Clean]

Beep sounds

[Delay] (M1)

EEPROM Version Number displayed

[Timer]

Main Code Version Number displayed

[Clock]

All Segments On

[More +]

Even Segments On

[Less –]

Odd Segments On

[Cancel]

End Factory Test Mode

Description of Error Codes

Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode. Each error code is four digits long and is created based on the following table.

Digit

 

 

Description

1st

Primary System:

1 – Local to the control circuit board

 

 

3

– Sensor or meat probe

 

 

4

– Control input

 

 

9

– Door lock

2nd

Measurable:

d – Diagnostic: measurable parameter

 

 

c – Control related, replace control

3rd

Secondary System: Sequential numbering

4th

Oven Cavity:

1 – Upper oven (or single cavity oven)

 

 

2

– Lower oven

 

 

c – Control specific

Diagnostic Code Display Mode may be started only within 60 seconds when powering up the control.

©2004 Maytag Services

16023522

17

Image 17
Contents Service Important Information Customer Service Support CenterTable of Contents Servicing Safety Practices for ServicerReceiving Oven Using the OvenProduct Safety Devices Connecting Range to GasBaking, Broiling, and Roasting Electrical RequirementsGeneral Information Placement of the Oven SpecificationsService Parts and AccessoriesGrounding ArningRange Description Troubleshooting Procedures Problem Possible Cause Correction Oven light does not operate Component Testing Procedures Spark module Test for voltage at terminals 120 VAC Seconds of powering up the unit Quick Test Mode for Electronic Range Control Sensor resistance Infinite Ohms Bake flashes Typical M1 Control Rocker Switch Maintop AssemblyTop Surface Valve and Spark Switch Control Board AssemblyManual Oven Door Latch Assembly Valve / Regulator AssemblyOpen Burner Oven SensorSide Panel Removal Oven Door Hinge ReceiverBackguard Storage Drawer RemovalPower Cord Oven Light AssemblyFrameless Door Disassembly Large and Standard Windows Large Window Frameless Oven DoorOven Door No Window Door Disassembly No WindowAppendix a Installation Instructions Models CP31200AD*, CG31200AD 200 BTU/HR or Less Inches Installation Drawings Installation Drawings Installation Instructions Model LPR1115AD 200 BTU/HR or Less Inches 16023522 200 BTU/HR or Less Inches Appliance Pressure Regulator Alternate Connectors Flame 16023522 Appendix B Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Surface Cooking Oven Cooking Self-Clean Oven Control select models Pilotless Ignition E F To change the clock to Hour format Care & Cleaning Do not USE ANY Cleaning Product Containing Chlorine Bleach Appendix C Conversion Instructions Models CP31200AD*, CG31200AD Conversion Instructions Models CP31200AD*, CG31200AD GAS Conversion Gas Conversion Orifice Conversion Range Adjustments Conversion Instructions Model LPR1115AD 03-04-00 16023522 Orifice Hood Gas Conversion Orifice Conversion Surface Burner Conversion Conventional Air Shutter