Converting Type 2 Pressure Regulator for Use with LP/Propane
1.Remove pressure regulator cap with a wrench.
2.Reverse pressure regulator cap.
• Cap must show “LP”.
3.Place pressure regulator cap on pressure regulator and tighten.
LP
4.While facing range front, turn orifice hoods counterclockwise 1½ to 2 turns or until snug.
•Use ½ inch open end or 90° offset open end wrench.
•Do not over tighten orifice hoods. If orifice hoods are over tightened, gas supply can be cutoff or orifice hoods can strip.
5.Open air shutter fully.
Cap | A |
Open Fully
B
Type 2 Pressure Regulator
Converting Surface Burners for Use with LP\Propane
1.Remove 4 burner control knobs from range.
•Exposes 2 screws on burner control panel.
2.Remove 2 screws from burner control panel.
•Panel drops slightly after screws are removed.
3.Grasp bottom of burner control panel, gently lift and pull out panel until clear of burner valve stems.
•After burner control panel clears valve stems, continue to roll panel until free from range. Set aside. See Pivot Point in figure.
•Gas valve and orifice hood are visible after burner control panel is removed.
A
B
Converting Surface Burners for Use with LP\Propane
6.Reassemble burner control panel after adjusting air shutter.
• See Adjusting Surface Burner Flame section.
D | C |
|
Burner Control Panel
9