FCI Home Appliances COGB 33061/L/WH, COGB33060/BL Electrical Requirements, General Information

Page 14

Cooktop & Installation Manual

Model COGB ENGLISH

Electrical Requirements

General Information

This appliance must be supplied with the proper voltage and frequency and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on the rating plate. We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified electrician.

After installation, have the electrician show you where your main cooktop disconnect is located. Check with your local utilities for electrical codes which apply in your area. Failure to wire your cooktop according to governing codes could result in a hazardous condition.

If there are no codes, your cooktop must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70 - Latest edition. You can get a copy by writing:

National Fire Protection Association

Battery march Park

Quincy. MA 02269

In Canada your cooktop must be wired and fused to meet the requirements of the Canadian Electrical Code.

Be sure the installation of this product in a mobile home conforms with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280.

If this standard does not apply, you must follow the standard for Manufactured Home Installations, ANSI A225.1 and Manufactured Home Installations, Sites and Communities and ANSI/NFPA 501A or with local codes.

You can get a copy of the Federal Standard by Writing:

Office of Mobile Home Standards HUD Building

451 7th Street, S.W. Washington, D.C. 24010

Electrical Connection

An adequate electrical supply and outlet must be used to operate the electrical parts of your cooktop.

WARNING

Electrical Grounding Instruction

Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Important:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

The power cord of this appliance is equipped with a 3- prong (grounding) plug which must be used with a properly grounded 3-hole outlet with a standard 120 Volt, 60 cycle AC household current. If you do not have a 3-hole grounded outlet, have a qualified electrician change your old one. A grounding adaptor will be needed to convert the old one until the outlet can be replaced. This method is only temporary, and a qualified electrician should test it to be sure it meets requirements.

Electrical Requirements

Do not under any circumstances cut or remove grounding prong from the cooktop cord.

GROUNDING PRONG

015

Figure 15.

14

Image 14
Contents Installation Manual Page Cooktop & Installation Manual Table of ContentsPlease read all instructions before using this appliance Before Starting InstallationCooktop Installed over Oven Installation Special WarningsProduct Dimensions and Cutout Requirements Important Preparation SuggestionsMobile Home Installation Gas and Electrical Line OpeningSolid surface countertop installation Cut Hazard Cooktop InstallationExcessive Weight Hazard StepDo not Over Tighten Never Tighten to More than 35 ft lbs of Torque Gas RequirementImportant Notes for Gas Connection Gas Connection Assure all pipe joint connections are gas tightEnglish Pressure Testing Pressure Test MethodElectrical Connection Electrical RequirementsGeneral Information Electrical RequirementsWiring diagram code FA51T40A Models CGB-3001 Replace all Injectors Conversion LP GasConverting Appliance for Use with LP Gas Save the orifices removed from the appliance for future useTo Convert Appliance for Use with NG Pressure Regulator ConversionBurner Ignition Low Flame AdjustmentBurner Ignition and Autoreignition Burner FlamesAu client ’installateurTables des matieres Avertissement Spéciaux Avant de Procéder à l’InstallationInstallation de la Table de Cuisson Au-Dessus du Four Que faire si vous sentez une odeur de gazDimensions et Dispositions pour la Découpe Suggestions Importantes de PréparationInstallation autocaravane Ouverture à pratiquer pour câble électrique et tuyau gazInstallation sur un plan de travail à surface solide Risque de coupure Installation de la Table de CuissonRisque du fait du poids excessif ÉtapeBien Serrer Mais PAS Trop Fort Conditions Requires Gaz Installez un emmanchement entre le régulateur et Raccordement du GazRobinet principal Vérification de la Pression Méthode de Test de PressionBranchement Electrique Conditions Requises ElectricitéInformation Général Requises ElectricitéSchéma électrique FA51T40A Modèles CGB-3001 Remplacez les injecteurs de tous les brûleurs Conversion Gaz PLConversion de l’Appareil pour Fonctionner au Gaz PL Conversion du Régulateur de Pression Pour Utiliser l’Appareil avec du Gaz NatuRel Remplacez tous les injecteurs PL avec desAllumage Brûleur Réglage Petite FlammeAllumage du Brûleur et Ré-allumage Au- tomatique Les Flammes du BrûleurLEA Y Conserve Estas INSTRUCCIONES. Instalador Tabela de ContenidoPagina ClienteQué hacer si detecta olor a gas Advertencias EspecialesAntes de comenzar la instalación Instalación de la placa sobre un hornoDimensiones del Producto y de Encastre Importantes Consejos de PreparaciónInstalación en Casas Móviles Figura 4. Abertura de la línea de gas y electricidadFigura 5. Instalación en encimeras de superficie sólida Peligro de corte Instalación de la Placa de CocciónPeso excesivo PasoFigura Paso Conexión del Gas Requisitos Observaciones importantes para la conexión del gasConexión del Gas Poder cerrar o abrir con facilidad el suministro deAtención Prueba de Presión Método de la prueba de presiónConexión Eléctrica Requisitos Conexión Eléctrica RequisitosConexión Eléctrica Peligro de descarga eléctricaFigura 16. Diagrama eléctrico FA51T40A Modelos CGB-3001 Sustituya todos los inyectores Conversión a Gas PLConversión del Electrodoméstico para su Uso con Gas PL Conversión del regulador de presión Conversión del Electrodoméstico para suUso con NG Encendido de los Quemadores Graduación de la Llama BajaEncendido y Re-encendido de los Que- madores Las llamas del quemadorPage 09FX1810 03/06