FCI Home Appliances COGB 33062/L/SS, COGB33060/BL To Convert Appliance for Use with NG

Page 17

Cooktop & Installation Manual

Model COGB ENGLISH

Pressure Regulator Conversion

Disconnect all electrical power, at the main circuit breaker or fuse box.

Shut off the gas supply to the cooktop by closing the manual shut-off valve.

Adjust the pressure regulator, by following the instructions (see figure 19):

Unscrew the cap.

Place your thumb against the flat side of the spring retainer and press down to remove the retainer.

Carefully look at the spring retainer to locate the NG or LP position.

Turn the spring retainer over so that LP is showing on the bottom.

Snap the retainer back into position.

 

CAP

 

GASKET

NG

LP / PROPANE

POSITION

POSITION

 

 

PRESSURE

 

REGULATOR

 

020

Figure 19. Pressure regulator conversion

To Convert Appliance for Use with NG

If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas (NG).

1.REPLACE ALL LP INJECTORS with NG injectors following the steps described on previous page, observe the number stamped on the side, this number codes the orifice diameter and its correct burner location see figure 20 (save the injectors removed from the appliances for future use).

2.INVERT CAP IN APPLIANCE PRESSURE REGULATOR following the steps described on the previous page carefully look at the spring retainer to locate the NG position (see figure 19).

3.ADJUST LOW FLAME (see “Low Flame Adjustment”).

After steps 1, 2 and 3 have been completed, check the appearance of each burner's flame at the Hi and Lo settings If the flames appear too large or too small, make sure all steps were completed correctly.

139

160

180

114

 

019

Figure 20. 4 burner Model (30” wide)

– NG conversion

17

Image 17
Contents Installation Manual Page Table of Contents Cooktop & Installation ManualCooktop Installed over Oven Installation Before Starting InstallationPlease read all instructions before using this appliance Special WarningsImportant Preparation Suggestions Product Dimensions and Cutout RequirementsGas and Electrical Line Opening Mobile Home InstallationSolid surface countertop installation Excessive Weight Hazard Cooktop InstallationCut Hazard StepDo not Over Tighten Never Tighten to More than 35 ft lbs of Torque Gas RequirementImportant Notes for Gas Connection Assure all pipe joint connections are gas tight Gas ConnectionEnglish Pressure Test Method Pressure TestingGeneral Information Electrical RequirementsElectrical Connection Electrical RequirementsWiring diagram code FA51T40A Models CGB-3001 Converting Appliance for Use with LP Gas Conversion LP GasReplace all Injectors Save the orifices removed from the appliance for future usePressure Regulator Conversion To Convert Appliance for Use with NGBurner Ignition and Autoreignition Low Flame AdjustmentBurner Ignition Burner FlamesAu client ’installateurTables des matieres Installation de la Table de Cuisson Au-Dessus du Four Avant de Procéder à l’InstallationAvertissement Spéciaux Que faire si vous sentez une odeur de gazSuggestions Importantes de Préparation Dimensions et Dispositions pour la DécoupeOuverture à pratiquer pour câble électrique et tuyau gaz Installation autocaravaneInstallation sur un plan de travail à surface solide Risque du fait du poids excessif Installation de la Table de CuissonRisque de coupure ÉtapeBien Serrer Mais PAS Trop Fort Conditions Requires Gaz Raccordement du Gaz Installez un emmanchement entre le régulateur etRobinet principal Méthode de Test de Pression Vérification de la PressionInformation Général Conditions Requises ElectricitéBranchement Electrique Requises ElectricitéSchéma électrique FA51T40A Modèles CGB-3001 Remplacez les injecteurs de tous les brûleurs Conversion Gaz PLConversion de l’Appareil pour Fonctionner au Gaz PL Rel Pour Utiliser l’Appareil avec du Gaz NatuConversion du Régulateur de Pression Remplacez tous les injecteurs PL avec desAllumage du Brûleur et Ré-allumage Au- tomatique Réglage Petite FlammeAllumage Brûleur Les Flammes du BrûleurPagina Tabela de ContenidoLEA Y Conserve Estas INSTRUCCIONES. Instalador ClienteAntes de comenzar la instalación Advertencias EspecialesQué hacer si detecta olor a gas Instalación de la placa sobre un hornoImportantes Consejos de Preparación Dimensiones del Producto y de EncastreFigura 4. Abertura de la línea de gas y electricidad Instalación en Casas MóvilesFigura 5. Instalación en encimeras de superficie sólida Peso excesivo Instalación de la Placa de CocciónPeligro de corte PasoFigura Paso Observaciones importantes para la conexión del gas Conexión del Gas RequisitosPoder cerrar o abrir con facilidad el suministro de Conexión del GasAtención Método de la prueba de presión Prueba de PresiónConexión Eléctrica Conexión Eléctrica RequisitosConexión Eléctrica Requisitos Peligro de descarga eléctricaFigura 16. Diagrama eléctrico FA51T40A Modelos CGB-3001 Sustituya todos los inyectores Conversión a Gas PLConversión del Electrodoméstico para su Uso con Gas PL Conversión del regulador de presión Conversión del Electrodoméstico para suUso con NG Encendido y Re-encendido de los Que- madores Graduación de la Llama BajaEncendido de los Quemadores Las llamas del quemadorPage 09FX1810 03/06