MQ PS4030 SAW — MAINTENANCE
F-N-R Control Adjustment
2
1.Correct hydraulic fluid level.
2.Plugged hydraulic oil filter
3.Loose or leaking fittings.
4.Ruptured/damaged hydraulic lines.
5.Faulty hydraulic pump.
Hydraulic Oil System
1. | Check hydraulic oil level daily. |
2. | When checking or adding hydraulic oil, place the machine |
| so the saw frame is level to get an accurate reading. |
3. | Hydraulic oil should be 1/2" to 1" in the Oil Reserve when |
| cold. |
4
1. Adjustment Nut
2. Rod End
1
3
2
1
3
4. | If hydraulic oil level is low add oil to 1/2" to 1". |
5. | Use |
6. | Change oil and filter annually. |
3. Push-Pull Cable
4. Neutral Safety Switch
Figure 63. F-N-R Control Adjustment
Control (Cable) adjustment for the
Hydraulic System Maintenance
WARNING |
| |
NEVER use your hand to find hydraulic |
| |
leaks. Use a piece of wood or cardboard. |
| |
Hydraulic fluid injected into the skin must |
| |
be treated by a knowledgable physician |
| |
immediately or severe injury or death can |
| |
occur. |
| |
Many hydraulic problems are a result of low fluid levels. Before | Figure 64. Oil Reserve Fill Line | |
checking any other possibilities, make sure the hydraulic fluid | ||
| ||
level is correct. |
|
MQ PS4030 SAW • OPERATION MANUAL — REV. #0 (02/29/08) — PAGE 53