DCA-600SSV — ENGINE OPERATING PANEL
The definitions below describe the controls and functions of the
1.Tachometer – Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.
2.Engine Warning Display (LED) Module – This module display’s the following engine failures:
A. Overheat Lamp – This lamp goes ON when |
|
the cooling water temperature rises abnormally. |
|
If the lamp goes ON during normal operation of |
|
the generator, the emergency shutdown device |
|
will stop the engine automatically. | WATER TEMP. |
B.Low Oil Pressure Lamp – During normal operation of the generator this lamp should remain OFF. When the Auto-
C.Low Fuel Level Lamp – When this lamp is
ON, it is time to stop the engine and add fuel. Remember to let the engine cool before adding fuel.
D. Charge Lamp – This lamp goes ON when the electrical charging system is not working properly.
E. Clogged Air Filter Lamp – This lamp goes ON when the air filter is clogged. If this lamp goes ON during normal operation of the generator, stop the engine and replace the air filter.
3.
4.Emergency Stop Button – Push this button inward to stop the engine in the event of an emergency. DO NOT use this button as a normal means of stopping the engine.
5.Oil Pressure Gauge – During normal operation this gauge be should read in the “GREEN” zone. When starting the generator the oil pressure mar read a little bit higher, but after the engine warms up the oil pressure should return to the green zone.
6.Water Temperature Gauge – During normal operation this gauge be should read in the “GREEN” zone.
7.Fuel Level Gauge – Indicates amount of diesel fuel remaining.
8.Battery Switch – This switch should be set to the ON position during normal operation. When the engine has been stop, place this switch in the OFF position. DO NOT turn this switch during normal operation, it could cause damage to the electrical equipment.
9.Preheat Switch – Press on to heat glow plugs in cold weather conditions.
10.Engine Speed Switch – This switch changes the engine speed from idle to normal.
11.Hour Meter Switch - Press this pushbutton switch to activate hour meter. Indicates the number hours equipment has been in operational use.