Multiquip DCA-25USIXF DCA-25USI Gauge READING/TERMINAL Panel Connections, Voltage Selector Switch

Page 26

DCA-25USI — GAUGE READING/TERMINAL PANEL CONNECTIONS

Voltage Selector Switch

The voltage selector switch (Figure 15) is located above the output terminal panel’s Hard Wire Hook-up Panel. It has been provided for ease of voltage selection.

Figure 15. Voltage Selector Switch

Voltage Selector Switch Locking Button

The voltage selector switch has a locking button to protect the generator and load from being switched while the engine is running. To lock the voltage selector switch, press and hold the red button located at the bottom of the switch.

CAUTION - CHANGINGVOLTAGES

NEVER change the position of the voltage selector switch while the engine is running. ALWAYS place circuit breaker in the open position before selecting voltage.

Generator OutputVoltages

A wide range of voltages are available to supply voltage for many different applications. Voltages are selected by using the voltage selector switch (Figure 15). To obtain some of the voltages as listed in Table 7 (see below) will require a fine adjustment using the voltage regulator (VR) control knob located on the control panel.

Table 7. Voltages Available

Three Phase

208V

220V

240V

416V

440V

480V

(Switchable)

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Phase

120V

127V

139V

240V

254V

277V

(Switchable)

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Amps

Table 8 shows the maximum amps the generator can pro- vide. DO NOT exceed the maximum amps as listed.

Table 8. Generator Maximum Amps

Rated Voltage

Maximum Amps

 

 

Single Phase

55.5 amps (4 wire)

120 Volt

 

 

 

Single Phase

27.8 amps (4 wire)

240 Volt

 

 

 

Three Phase

60 amps

240 Volt

 

 

 

Three Phase

30 amps

480 Volt

 

 

 

GFCI Receptacle Load Capability

The load capability of the GFCI receptacles is directly re- lated to the voltage being supplied at either the output termi- nals or the 2 twist lock auxiliary receptacles.

Tables 9 and 10 show what amount of current is available at the GFCI receptacles when the output terminals and twist lock receptacles are in use. Be careful that your load does not to exceed the available current capability at the recep- tacles.

Table 9. GFCI Receptacle Load Capability (1Ø)

KW in Use

Available Load

Twist-Lock (CS6369)

Current (Amps)

1Ø 240/120V

GFCI Duplex NEMA

5-20R 120V

 

14.4

0

13.2

5 amps per receptacle

12.0

10 amps per receptacle

10.8

15 amps per receptacle

9.6

20 amps per receptacle

 

 

Table 10. GFCI Receptacle Load Capability (3Ø)

 

 

KVA in Use

Available Load

(UVWO Terminals)

Current (Amps)

3Ø 240/480V

GFCI Duplex NEMA

5-20R 120V

 

25

0

20.8

5 amps per receptacle

16.7

10 amps per receptacle

12.5

15 amps per receptacle

8.4

20 amps per receptacle

PAGE 26 — DCA-25USIXF/DCA-25USI2XF — OPERATION AND PARTS MANUAL — REV. #8 (05/08/09)

Image 26
Contents Model DCA-25USIXF Model DCA-25USI2XF Diesel engine exhaust and some DCA-25USIXF/DCA-25USI2XF- Proposition 65WARNINGDCA-25USIXF/DCA-25USI2XF-TABLE of Contents DCA-25USIXF/DCA-25USI2XF- Parts Ordering Procedures Ordering parts has never been easierDCA-25USIXF/DCA-25USI2XF- Specifications Generator SpecificationsDCA-25USIXF/DCA-25USI2XF- Dimensions TOP, Side and Front DimensionsDCA-25USIXF/DCA-25USI2XF- Safety Message Alert Symbols Hazard SymbolsDCA-25USIXF/DCA-25USI2XF- Safety Message Alert Symbols Injury People General SafetyDCA-25USIXF/DCA-25USI2XF- Rules for Safe Operation Carbon monoxide gasMaintenance Safety DCA-25USIXF/DCA-25USI2XF- Rules for Safe OperationBattery Safety Use well insulated gloves when picking up the batteryDeath Towing and Transporting Safety Guidelines section in this manualDCA-25USIXF/DCA-25USI2XF- Decals Generator DecalsDCA-25USIXF/DCA-25USI2XF- Decals DCA-25USIXF/DCA-25USI2XF- Installation Typical Generator Grounding ApplicationWhen connecting the generator Outdoor InstallationIndoor Installation MountingDCA-25USIXF/DCA-25USI2XF- General Information  Two auxilliary circuit breakers, 250V @50 ampsDCA-25USIXF/DCA-25USI2XF- Major Components Major ComponentsDCA-25USIXF/DCA-25USI2XF- Generator Control Panel Generator Control PanelDCA-25USIXF/DCA-25USI2XF- Engine Operating Panel Engine Operating PanelOutput Terminal Familiarization DCA-25USIXF/DCA-25USI2XF- Output Terminal PanelOutput Terminal Panel DCA-25USIXF/DCA-25USI2XF- Output Terminal Panel 120VAC Gfci ReceptaclesConnecting Loads Over Current RelayDCA-25USIXF/DCA-25USI2XF- Load APPLICATION/MAXIMUM Single Phase LoadThree Phase Load Motors and motor-drivenGenerator OutputVoltages Voltage Selector SwitchDCA-25USI Gauge READING/TERMINAL Panel Connections Maximum AmpsDCA-25USI Gauge READING/TERMINAL Panel Connections Voltage selector switchChange-Over Switch Reading Voltage3Ø 240/139 Output Terminal Lug Voltages Three-Phase PositionUvwo Terminal Output Voltages 3Ø 208V/1Ø120V Output Terminal Lug Voltages3Ø 480/277 Output Terminal Lug Voltages 1Ø 240V/120V Output Terminal Lug VoltagesLubrication Oil DCA-25USIXF/DCA-25USI2XF- SetupCircuit Breakers Fuel CheckRefueling DCA-25USIXF/DCA-25USI2XF- SetupRefueling Procedure Operation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Must be less than 50%Wiring BatteryBattery Cable Installation AlternatorEngines exhaust contains harmful emissions DCA-25USIXF/DCA-25USI2XF- Generator START-UP ProcedureBefore Starting Direct exhaust away from nearby personnelIgnition Switch Start Position Oil Pressure Gauge Emergency Shut-down Procedure DCA-25USIXF/DCA-25USI2XF- Generator SHUT-DOWN ProcedureNormal Shut-down Procedure Automatic Shut-down SystemDCA-25USIXF/DCA-25USI2XF- Maintenance DCA-25USIXF/DCA-25USI2XF- Maintenance Brakes DCA-25USIXF/DCA-25USI2XF-TRAILER MaintenanceBrake Adjustment Check the wheel and drum for free rotationTireWear/Inflation DCA-25USIXF/DCA-25USI2XF-TRAILER MaintenanceTires/Wheels/Lug Nuts SuspensionStart all wheel lug nuts by hand DCA-25USIXF/DCA-25USI2XF-TRAILER MaintenanceLug Nut Torque Requirements DCA-25USIXF/DCA-25USI2XF-TRAILERWIRING Diagram Trailer/Towing Vehicle Wiring DiagramDCA-25USIXF/DCA-25USI2XF- Enginewiring Diagram Engine Wiring DiagramDCA-25USIXF/DCA-25USI2XF- Enginewiring Diagram DCA-25USIXF/DCA-25USI2XF- Generatorwiring Diagram Generator Wiring DiagramStarter does not run DCA-25USIXF/DCA-25USI2XF-TROUBLESHOOTING EngineEngine does not start DCA-25USIXF/DCA-25USI2XF-TROUBLESHOOTING Engine DCA-25USIXF/DCA-25USI2XF-TROUBLESHOOTING Generator Generator TroubleshootingSample Parts List DCA-25USIXF/DCA-25USI2XF- Explanation of Code in RemarksDCA-25USIXF/DCA-25USI2XF- Suggested Spare Parts Qty DescriptionDCA-25USIXF/DCA-25USI2XF- Generator Assy DCA-25USIXF/DCA-25USI2XF- Generator Assy DCA-25USIXF- Control BOX Assy DCA-25USIXF- Control BOX Assy DCA-25USIXF- Control BOX Assy DCA-25USIXF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USIXF- Engine ANDvRADIATOR Assy DCA-25USIXF- Engine and Radiator Assy DCA-25USIXF- Engine and Radiator Assy 0150000018 M9602000003M9200200004 0199901600DCA-25USI2XF- Engine and Radiator Assy M9200100904 M19232001248944567412 0150000016DCA-25USI2XF- Engine and Radiator Assy M1316100603 DCA-25USIXF/DCA-25USI2XF- Outputterminal Assy Output Terminal AssyM9220000104 M1230700003M9220000004 0039308000DCA-25USIXF/DCA-25USI2XF- Battery Assy M9103000304 0602220185M9310500014 0602220920DCA-25USIXF- Muffler Assy DCA-25USIXF Muffler Assy DCA-25USI2XF- Muffler Assy M1333300204 M1332000512M1333200304 M1333003013DCA-25USIXF/DCA-25USI2XF- Fueltank Assy 0605501098 M13630013020605505072 0605516090DCA-25USIXF- Enclosure Assy M1413100003 M1413002502M1493000004 0603306797 PLUG, 1-1/2 0016910030DCA-25USIXF- Enclosure Assy 27B M1495300604 M144530010327A M1495300504 M1445400103DCA-25USIXF- Enclosure Assy M9112100504 51A C931250000452A 0030006000 M1435000903DCA-25USI2XF- Enclosure Assy M1413600004 M1413003902M1493000704 M1423002402DCA-25USI2XF- Enclosure Assy M1443400103 M144330220334A M1493305104 35A M1493305204DCA-25USI2XF- Enclosure Assy M1433300003 58A C931250000459A 0030006000 M1433001103DCA-25USIXF/DCA-25USI2XF- Rubber Seals Assy 0229200630 02292007900314500560 0228901220DCA-25USIXF/DCA-25USI2XF- Nameplate and Decals Assy DCA-25USIXF/DCA-25USI2XF- Nameplate and Decals Assy Terms and Conditions of Sale Parts FreightpolicyPage Tel Fax 972