Multiquip operation manual DCA-25USIXF/DCA-25USI2XF- Maintenance

Page 38

DCA-25USIXF/DCA-25USI2XF— MAINTENANCE

TABLE 14. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

Drain Bottom of Fuel Tank

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Check Fuel Filter/Water Seperator Bowl

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Blowby Hose * 2

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check all Hoses and Clamps

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

 

*2

If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

 

*3

Replace primary air filter element when restriction indicator shows a vaccumm of 625 mm. (25 in.) H20

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks. Use Table 14 as a general maintenance guideline. Engine Side, refer to the Engine Instruction Manual

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result.This can lead to a loss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Air Cleaner

Every 50 hours: Remove air cleaner element and clean the heavy duty paper element with kerosene, or foam element with liquid detergent and hot water. Wrap foam element in a cloth and squeeze dry. For heavy duty paper element, wipe excess kerosene with towel.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner.When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows “RED” meaning the element needs changing. After changing the air element, press the dust indicator button to reset the indicator.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations). Always pour through the mesh filter.

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally remove the drain cock and drain the contents. During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

PAGE 38 — DCA-25USIXF/DCA-25USI2XF — OPERATION AND PARTS MANUAL — REV. #8 (05/08/09)

Image 38
Contents Model DCA-25USIXF Model DCA-25USI2XF Diesel engine exhaust and some DCA-25USIXF/DCA-25USI2XF- Proposition 65WARNINGDCA-25USIXF/DCA-25USI2XF-TABLE of Contents DCA-25USIXF/DCA-25USI2XF- Parts Ordering Procedures Ordering parts has never been easierDCA-25USIXF/DCA-25USI2XF- Specifications Generator SpecificationsDCA-25USIXF/DCA-25USI2XF- Dimensions TOP, Side and Front DimensionsDCA-25USIXF/DCA-25USI2XF- Safety Message Alert Symbols Hazard SymbolsDCA-25USIXF/DCA-25USI2XF- Safety Message Alert Symbols Injury People General SafetyDCA-25USIXF/DCA-25USI2XF- Rules for Safe Operation Carbon monoxide gasMaintenance Safety DCA-25USIXF/DCA-25USI2XF- Rules for Safe OperationBattery Safety Use well insulated gloves when picking up the batteryDeath Towing and Transporting Safety Guidelines section in this manualDCA-25USIXF/DCA-25USI2XF- Decals Generator DecalsDCA-25USIXF/DCA-25USI2XF- Decals DCA-25USIXF/DCA-25USI2XF- Installation Typical Generator Grounding ApplicationWhen connecting the generator Outdoor InstallationIndoor Installation MountingDCA-25USIXF/DCA-25USI2XF- General Information  Two auxilliary circuit breakers, 250V @50 ampsDCA-25USIXF/DCA-25USI2XF- Major Components Major ComponentsDCA-25USIXF/DCA-25USI2XF- Generator Control Panel Generator Control PanelDCA-25USIXF/DCA-25USI2XF- Engine Operating Panel Engine Operating PanelOutput Terminal Familiarization DCA-25USIXF/DCA-25USI2XF- Output Terminal PanelOutput Terminal Panel DCA-25USIXF/DCA-25USI2XF- Output Terminal Panel 120VAC Gfci ReceptaclesConnecting Loads Over Current RelayDCA-25USIXF/DCA-25USI2XF- Load APPLICATION/MAXIMUM Single Phase LoadThree Phase Load Motors and motor-drivenGenerator OutputVoltages Voltage Selector SwitchDCA-25USI Gauge READING/TERMINAL Panel Connections Maximum AmpsDCA-25USI Gauge READING/TERMINAL Panel Connections Voltage selector switchChange-Over Switch Reading Voltage3Ø 240/139 Output Terminal Lug Voltages Three-Phase PositionUvwo Terminal Output Voltages 3Ø 208V/1Ø120V Output Terminal Lug Voltages3Ø 480/277 Output Terminal Lug Voltages 1Ø 240V/120V Output Terminal Lug VoltagesLubrication Oil DCA-25USIXF/DCA-25USI2XF- SetupCircuit Breakers Fuel CheckRefueling DCA-25USIXF/DCA-25USI2XF- SetupRefueling Procedure Operation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Must be less than 50%Wiring BatteryBattery Cable Installation AlternatorEngines exhaust contains harmful emissions DCA-25USIXF/DCA-25USI2XF- Generator START-UP ProcedureBefore Starting Direct exhaust away from nearby personnelIgnition Switch Start Position Oil Pressure Gauge Emergency Shut-down Procedure DCA-25USIXF/DCA-25USI2XF- Generator SHUT-DOWN ProcedureNormal Shut-down Procedure Automatic Shut-down SystemDCA-25USIXF/DCA-25USI2XF- Maintenance DCA-25USIXF/DCA-25USI2XF- Maintenance Brakes DCA-25USIXF/DCA-25USI2XF-TRAILER MaintenanceBrake Adjustment Check the wheel and drum for free rotationTireWear/Inflation DCA-25USIXF/DCA-25USI2XF-TRAILER MaintenanceTires/Wheels/Lug Nuts SuspensionStart all wheel lug nuts by hand DCA-25USIXF/DCA-25USI2XF-TRAILER MaintenanceLug Nut Torque Requirements DCA-25USIXF/DCA-25USI2XF-TRAILERWIRING Diagram Trailer/Towing Vehicle Wiring DiagramDCA-25USIXF/DCA-25USI2XF- Enginewiring Diagram Engine Wiring DiagramDCA-25USIXF/DCA-25USI2XF- Enginewiring Diagram DCA-25USIXF/DCA-25USI2XF- Generatorwiring Diagram Generator Wiring DiagramStarter does not run DCA-25USIXF/DCA-25USI2XF-TROUBLESHOOTING EngineEngine does not start DCA-25USIXF/DCA-25USI2XF-TROUBLESHOOTING Engine DCA-25USIXF/DCA-25USI2XF-TROUBLESHOOTING Generator Generator TroubleshootingSample Parts List DCA-25USIXF/DCA-25USI2XF- Explanation of Code in RemarksDCA-25USIXF/DCA-25USI2XF- Suggested Spare Parts Qty DescriptionDCA-25USIXF/DCA-25USI2XF- Generator Assy DCA-25USIXF/DCA-25USI2XF- Generator Assy DCA-25USIXF- Control BOX Assy DCA-25USIXF- Control BOX Assy DCA-25USIXF- Control BOX Assy DCA-25USIXF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USI2XF- Control BOX Assy DCA-25USIXF- Engine ANDvRADIATOR Assy DCA-25USIXF- Engine and Radiator Assy DCA-25USIXF- Engine and Radiator Assy 0150000018 M9602000003M9200200004 0199901600DCA-25USI2XF- Engine and Radiator Assy M9200100904 M19232001248944567412 0150000016DCA-25USI2XF- Engine and Radiator Assy M1316100603 DCA-25USIXF/DCA-25USI2XF- Outputterminal Assy Output Terminal AssyM9220000104 M1230700003M9220000004 0039308000DCA-25USIXF/DCA-25USI2XF- Battery Assy M9103000304 0602220185M9310500014 0602220920DCA-25USIXF- Muffler Assy DCA-25USIXF Muffler Assy DCA-25USI2XF- Muffler Assy M1333300204 M1332000512M1333200304 M1333003013DCA-25USIXF/DCA-25USI2XF- Fueltank Assy 0605501098 M13630013020605505072 0605516090DCA-25USIXF- Enclosure Assy M1413100003 M1413002502M1493000004 0603306797 PLUG, 1-1/2 0016910030DCA-25USIXF- Enclosure Assy 27B M1495300604 M144530010327A M1495300504 M1445400103DCA-25USIXF- Enclosure Assy M9112100504 51A C931250000452A 0030006000 M1435000903DCA-25USI2XF- Enclosure Assy M1413600004 M1413003902M1493000704 M1423002402DCA-25USI2XF- Enclosure Assy M1443400103 M144330220334A M1493305104 35A M1493305204DCA-25USI2XF- Enclosure Assy M1433300003 58A C931250000459A 0030006000 M1433001103DCA-25USIXF/DCA-25USI2XF- Rubber Seals Assy 0229200630 02292007900314500560 0228901220DCA-25USIXF/DCA-25USI2XF- Nameplate and Decals Assy DCA-25USIXF/DCA-25USI2XF- Nameplate and Decals Assy Terms and Conditions of Sale Parts FreightpolicyPage Tel Fax 972