Multiquip DCA-125USJ 50 HZ- Rules for Safe Operation, Towing Safety Precautions

Page 13

DCA-125USJ (50 HZ)— RULES FOR SAFE OPERATION

Towing Safety Precautions

CAUTION:

Conform to Department ofTransportation (DOT) Safety Towing Regulations before towing generator.

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of suggestions should be used when towing your generator:

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts.This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

DOT Requirements include the following:

zConnect and test electric brake operation.

zSecure portable power cables in cable tray with tie wraps.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest and first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

DCA-125USJ (50 HZ) — OPERATION AND PARTS MANUAL — REV. #0 (03/11/05) — PAGE 13

Image 13
Contents Model DCA-125USJ Page Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-125USJ 50 HZ- Specifications Dimensions DCA-125USJ 50 HZ- Dimensions TOP, Side and FrontFor Your Safety and the Safety of Others DCA-125USJ 50 HZ Safety Message Alert SymbolsOver Speed Conditions Sight and Hearing hazard DCA-125USJ 50 HZ Safety Message Alert SymbolsDCA-125USJ 50 HZ Rules for Safe Operation Electrical shock, electrocution, and even death DCA-125USJ 50 HZ Rules for Safe OperationRadiator DCA-125USJ 50 HZ- Rules for Safe Operation BatteryTransporting DCA-125USJ 50 HZ- Rules for Safe Operation Towing Safety PrecautionsDCA-125USJ 50 HZ- Installation Outdoor Installation DCA-125USJ 50 HZ- InstallationMounting Generator with Trailer DCA-125USJ 50 HZ-TOWING Safety PrecautionsExplanation of Chart DCA-125USJ 50 HZ-TRAILER SpecificationsFrame Width Measurement is from fender to fender Coupler Type of hitch used on the trailer for towingGenerator Decals DCA-125USJ 50 HZ- Generator DecalsDCA-125USJ 50 HZ- Generator Decals DCA-125USJ 50 HZ- General Information Generator Major Components DCA-125USJ 50 HZ- Major ComponentsPage Generator Control Panel DCA-125USJ 50 HZ- Generator Control PanelEngine Operating Panel DCA-125USJ 50 HZ- Engine Operating PanelDCA-125USJ 50 HZ- Engine Operating Panel Output Terminal Familiarization DCA-125USJ 50 HZ- Output Terminal Panel FamiliarizationTwist Lock Dual Voltage 100/200 VAC Receptacles 100VAC Gfci ReceptaclesBlower Fan Connecting LoadsThree Phase Load Single Phase LoadDCA-125USJ 50 HZ- Load Application Motors and motor-drivenDCA-125USJ 50 HZ- Generator Outputs Voltage Selector SwitchGenerator OutputVoltages Generator AmperageDCA-125USJ 50 HZ- Gauge Reading How to Read the OutputTerminal GaugesReading Amperage Uvwo Terminal Output Voltages DCA-125USJ 50 HZ- Output Terminal Panel Connections3Ø 220/127 Output Terminal Lug Voltages 3Ø 200V/1Ø115V Output Terminal Lug Voltages3Ø 440/254 Output Terminal Lug Voltages DCA-125USJ 50 HZ- Output Terminal Panel Connections1Ø 200V/100V Output Terminal Lug Voltages Circuit Breakers DCA-125USJ 50 HZ- PRE-SETUPLubrication Oil Fuel CheckRefueling Procedure DCA-125USJ 50 HZ- PRE-SETUPContact and/or inhaling fumes ALWAYS! place trailer on firm level ground before refuelingAir Cleaner Fan Belt Tension Cleaning the RadiatorOperation FreezingWeather Must be less than 50%When connecting battery do the following Battery Cable InstallationWiring AlternatorBefore Starting DCA-125USJ 50 HZ- Generator START-UP Procedure ManualLED on Starting ManualOil Pressure Gauge Starting Auto Mode DCA-125USJ 50 HZ- Generator START-UP Procedure Auto ModeEmergency Shutdown Procedure DCA-125USJ 50 HZ- Generator SHUT-DOWN ProcedureShutdown Procedure DCA-125USJ 50 HZ- Maintenance Check Oil Level Air RemovalReplacing Oil Filter Replacing Fuel FilterDCA-125USJ 50 HZ Operation and Parts Manual REV. #0 03/11/05 Brake Adjustment DCA-125USJ 50 HZ-TRAILER Brakes MaintenanceBrakes Hydraulic Surge BrakesTires/Wheels/Lug Nuts DCA-125USJ 50 HZ-TRAILER MaintenanceTire Wear/Inflation SuspensionLug Nut Torque Requirements DCA-125USJ 50 HZ-TRAILER MaintenanceStart all wheel lug nuts by hand Trailer/Towing Vehicle Wiring Diagram DCA-125USJ 50 HZ-TRAILERWIRING DiagramGenerator Wiring Diagram DCA-125USJ 50 HZ- Generatorwiring DiagramEngine Wiring Diagram DCA-125USJ 50 HZ- Enginewiring DiagramGenerator Troubleshooting DCA-125USJ 50 HZ-TROUBLESHOOTING GeneratorEngine Controller Troubleshooting DCA-125USJ 50 HZ-TROUBLESHOOTING Engine ControllerItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description To 3 UnitsDCA-125USJ 50 HZ- Generator Assy DCA-125USJ 50 HZ- Generator Assy DCA-125USJ 50 HZ- Control BOX Assy 0330000180 M32130007020601808823 LAF3630010393PDCA-125USJ 50 HZ- Control BOX Assy DCA-125USJ 50 HZ- Control BOX Assy DCA-125USJ 50 HZ- Engine and Radiator Assy 0602041292 M3923200054RE504836 0602042594Engine & Radiator Assy DCA-125USJ 50 HZ- Engine and Radiator Assy DCA-125USJ 50 HZ- Outputterminal Assy DCA-125USJ 50 HZ- Outputterminal Assy DCA-125USJ 50 HZ- Battery Assy 4D-2 0602220196M9310500404 M9103000504DCA-125USJ 50 HZ- Muffler Assy 0017112030 M3330100402M3333000903 M3333200304DCA-125USJ 50 HZ- Fueltank Assy DCA-125USJ 50 HZ- Fuel Tank Assy Enclosure #1 Assy DCA-125USJ 50 HZ- Enclosure #1 AssyM3363300303 M34130018120016910030 0603306797DCA-125USJ 50 HZ- Enclosure #1 Assy 24A M3493201204 24A M34932006140010114040 25A 0030014000Enclosure #2 Assy DCA-125USJ 50 HZ- Enclosure #2 AssyM3443000812 M3443000802M3493303203 M3443000904DCA-125USJ 50 HZ- Rubber Seals Assy 0229201130 02292008700229201240 0228900660DCA-125USJ 50 HZ- Nameplate and Decals Assy M15000020 M1550000204M1550000703 M15000070Terms and Conditions of Sale Parts DCA-125USJ 50 HZ Operation and Parts Manual REV. #0 03/11/05 Your Local Dealer is