Multiquip DCA-125USJ operation manual Starting Manual, LED on

Page 39

DCA-125USJ (50 HZ)— GENERATOR START-UP PROCEDURE (MANUAL)

Starting (Manual)

9. The generator's frequency meter (Figure 45) should be

 

displaying the 60 cycle output frequency in HERTZ.

8.Place the MPEC Control Switch in the MANUAL position to start the engine (Figure 42).

Figure 42. MPEC Control Switch

(Manual Position)

In cold weather conditions, placing the MPEC Control Switch in the MANUAL position will preheat and start the engine AUTOMATICALLY. The Preheat Lamp (Figure 43) will turn off when the engine has started.

7.Once the engine starts, let the engine run for 1-2 minutes. Listen for any abnormal noises.

Figure 45. Frequency Meter (Hz)

10.The generator's AC-voltmeter (Figure 46) will display the generator’s output in VOLTS. If the voltage is not within the specified tolerance, use the voltage adjustment control knob (Figure 47) to increase or decrease the desired voltage.

Figure 43. Pre-Heat Lamp

8.Verify that the Engine Running status LED on the MPEC unit (Figure 44) is ON (lit) after the engine has been started.

Figure 44. Engine Running

LED (ON)

Figure 46. Voltmeter

Figure 47. Voltage Adjust Control Knob

11.The ammeter (Figure 48) will indicate zero amps with no load applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator.

Figure 48. Ammeter (No Load)

DCA-125USJ (50 HZ) — OPERATION AND PARTS MANUAL — REV. #0 (03/11/05) — PAGE 39

Image 39
Contents Model DCA-125USJ Page Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-125USJ 50 HZ- Specifications Dimensions DCA-125USJ 50 HZ- Dimensions TOP, Side and FrontFor Your Safety and the Safety of Others DCA-125USJ 50 HZ Safety Message Alert SymbolsOver Speed Conditions Sight and Hearing hazard DCA-125USJ 50 HZ Safety Message Alert SymbolsDCA-125USJ 50 HZ Rules for Safe Operation DCA-125USJ 50 HZ Rules for Safe Operation Electrical shock, electrocution, and even deathRadiator Battery DCA-125USJ 50 HZ- Rules for Safe OperationTransporting DCA-125USJ 50 HZ- Rules for Safe Operation Towing Safety PrecautionsDCA-125USJ 50 HZ- Installation DCA-125USJ 50 HZ- Installation Outdoor InstallationMounting Generator with Trailer DCA-125USJ 50 HZ-TOWING Safety PrecautionsCoupler Type of hitch used on the trailer for towing DCA-125USJ 50 HZ-TRAILER SpecificationsExplanation of Chart Frame Width Measurement is from fender to fenderGenerator Decals DCA-125USJ 50 HZ- Generator DecalsDCA-125USJ 50 HZ- Generator Decals DCA-125USJ 50 HZ- General Information Generator Major Components DCA-125USJ 50 HZ- Major ComponentsPage Generator Control Panel DCA-125USJ 50 HZ- Generator Control PanelEngine Operating Panel DCA-125USJ 50 HZ- Engine Operating PanelDCA-125USJ 50 HZ- Engine Operating Panel Output Terminal Familiarization DCA-125USJ 50 HZ- Output Terminal Panel FamiliarizationTwist Lock Dual Voltage 100/200 VAC Receptacles 100VAC Gfci ReceptaclesBlower Fan Connecting LoadsMotors and motor-driven Single Phase LoadThree Phase Load DCA-125USJ 50 HZ- Load ApplicationGenerator Amperage Voltage Selector SwitchDCA-125USJ 50 HZ- Generator Outputs Generator OutputVoltagesHow to Read the OutputTerminal Gauges DCA-125USJ 50 HZ- Gauge ReadingReading Amperage 3Ø 200V/1Ø115V Output Terminal Lug Voltages DCA-125USJ 50 HZ- Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø 220/127 Output Terminal Lug VoltagesDCA-125USJ 50 HZ- Output Terminal Panel Connections 3Ø 440/254 Output Terminal Lug Voltages1Ø 200V/100V Output Terminal Lug Voltages Fuel Check DCA-125USJ 50 HZ- PRE-SETUPCircuit Breakers Lubrication OilALWAYS! place trailer on firm level ground before refueling DCA-125USJ 50 HZ- PRE-SETUPRefueling Procedure Contact and/or inhaling fumesMust be less than 50% Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherAlternator Battery Cable InstallationWhen connecting battery do the following WiringBefore Starting DCA-125USJ 50 HZ- Generator START-UP Procedure ManualLED on Starting ManualOil Pressure Gauge Starting Auto Mode DCA-125USJ 50 HZ- Generator START-UP Procedure Auto ModeDCA-125USJ 50 HZ- Generator SHUT-DOWN Procedure Emergency Shutdown ProcedureShutdown Procedure DCA-125USJ 50 HZ- Maintenance Replacing Fuel Filter Air RemovalCheck Oil Level Replacing Oil FilterDCA-125USJ 50 HZ Operation and Parts Manual REV. #0 03/11/05 Hydraulic Surge Brakes DCA-125USJ 50 HZ-TRAILER Brakes MaintenanceBrake Adjustment BrakesSuspension DCA-125USJ 50 HZ-TRAILER MaintenanceTires/Wheels/Lug Nuts Tire Wear/InflationDCA-125USJ 50 HZ-TRAILER Maintenance Lug Nut Torque RequirementsStart all wheel lug nuts by hand Trailer/Towing Vehicle Wiring Diagram DCA-125USJ 50 HZ-TRAILERWIRING DiagramGenerator Wiring Diagram DCA-125USJ 50 HZ- Generatorwiring DiagramEngine Wiring Diagram DCA-125USJ 50 HZ- Enginewiring DiagramGenerator Troubleshooting DCA-125USJ 50 HZ-TROUBLESHOOTING GeneratorEngine Controller Troubleshooting DCA-125USJ 50 HZ-TROUBLESHOOTING Engine ControllerItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description To 3 UnitsDCA-125USJ 50 HZ- Generator Assy DCA-125USJ 50 HZ- Generator Assy DCA-125USJ 50 HZ- Control BOX Assy LAF3630010393P M32130007020330000180 0601808823DCA-125USJ 50 HZ- Control BOX Assy DCA-125USJ 50 HZ- Control BOX Assy DCA-125USJ 50 HZ- Engine and Radiator Assy 0602042594 M39232000540602041292 RE504836Engine & Radiator Assy DCA-125USJ 50 HZ- Engine and Radiator Assy DCA-125USJ 50 HZ- Outputterminal Assy DCA-125USJ 50 HZ- Outputterminal Assy DCA-125USJ 50 HZ- Battery Assy M9103000504 06022201964D-2 M9310500404DCA-125USJ 50 HZ- Muffler Assy M3333200304 M33301004020017112030 M3333000903DCA-125USJ 50 HZ- Fueltank Assy DCA-125USJ 50 HZ- Fuel Tank Assy Enclosure #1 Assy DCA-125USJ 50 HZ- Enclosure #1 Assy0603306797 M3413001812M3363300303 0016910030DCA-125USJ 50 HZ- Enclosure #1 Assy 25A 0030014000 24A M349320061424A M3493201204 0010114040Enclosure #2 Assy DCA-125USJ 50 HZ- Enclosure #2 AssyM3443000904 M3443000802M3443000812 M3493303203DCA-125USJ 50 HZ- Rubber Seals Assy 0228900660 02292008700229201130 0229201240DCA-125USJ 50 HZ- Nameplate and Decals Assy M15000070 M1550000204M15000020 M1550000703Terms and Conditions of Sale Parts DCA-125USJ 50 HZ Operation and Parts Manual REV. #0 03/11/05 Your Local Dealer is