Multiquip DCA-125USJ 50 HZ-TROUBLESHOOTING Generator, Generator Troubleshooting

Page 52

DCA-125USJ (50 HZ)—TROUBLESHOOTING (GENERATOR)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 16 shown below for diagnosis of the Generator. If the problem cannot be remedied, consult our company's business office or service plant.

TABLE 16. GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

No Voltage Output

AC Voltmeter defective?

Check output voltage using a voltmeter.

 

 

 

 

Is wiring connection loose?

Check wiring and repair.

 

 

 

 

Is AVR defective?

Replace if necessary.

 

 

 

 

Defective Rotating Rectifier?

Check and replace.

 

 

 

 

Defective Exciter Field?

Check for 17.3 ohms across J & K on CN1

 

 

 

Low Voltage Output

Is engine speed correct?

Turn engine throttle lever to "High".

 

 

 

 

Is wiring connections loose?

Check wiring and repair.

 

 

 

 

Defective AVR?

Replace if necessary.

 

 

 

High Voltage Output

Is wiring connections loose?

Check wiring and repair.

 

 

 

 

Defective AVR?

Replace if necessary.

 

 

 

Circuit Breaker Tripped

Short Circuit in load?

Check load and repair.

 

 

 

 

Over current?

Confirm load requirements and reduce.

 

 

 

 

Defective circuit breaker?

Check and replace.

 

 

 

 

Over current Relay actuated?

Confirm load requirement and replace.

 

 

 

PAGE 52 — DCA-125USJ (50 HZ) — OPERATION AND PARTS MANUAL — REV. #0 (03/11/05)

Image 52
Contents Model DCA-125USJ Page Heres HOW to GET Help Wilmington Ave Carson, CATable of Contents Parts Ordering Procedures When ordering parts Please supply the following informationDCA-125USJ 50 HZ- Specifications DCA-125USJ 50 HZ- Dimensions TOP, Side and Front DimensionsDCA-125USJ 50 HZ Safety Message Alert Symbols For Your Safety and the Safety of OthersDCA-125USJ 50 HZ Safety Message Alert Symbols Over Speed Conditions Sight and Hearing hazardDCA-125USJ 50 HZ Rules for Safe Operation Electrical shock, electrocution, and even death DCA-125USJ 50 HZ Rules for Safe OperationRadiator DCA-125USJ 50 HZ- Rules for Safe Operation BatteryTransporting Towing Safety Precautions DCA-125USJ 50 HZ- Rules for Safe OperationDCA-125USJ 50 HZ- Installation Outdoor Installation DCA-125USJ 50 HZ- InstallationMounting DCA-125USJ 50 HZ-TOWING Safety Precautions Generator with TrailerDCA-125USJ 50 HZ-TRAILER Specifications Explanation of ChartFrame Width Measurement is from fender to fender Coupler Type of hitch used on the trailer for towingDCA-125USJ 50 HZ- Generator Decals Generator DecalsDCA-125USJ 50 HZ- Generator Decals DCA-125USJ 50 HZ- General Information DCA-125USJ 50 HZ- Major Components Generator Major ComponentsPage DCA-125USJ 50 HZ- Generator Control Panel Generator Control PanelDCA-125USJ 50 HZ- Engine Operating Panel Engine Operating PanelDCA-125USJ 50 HZ- Engine Operating Panel DCA-125USJ 50 HZ- Output Terminal Panel Familiarization Output Terminal Familiarization100VAC Gfci Receptacles Twist Lock Dual Voltage 100/200 VAC ReceptaclesConnecting Loads Blower FanSingle Phase Load Three Phase LoadDCA-125USJ 50 HZ- Load Application Motors and motor-drivenVoltage Selector Switch DCA-125USJ 50 HZ- Generator OutputsGenerator OutputVoltages Generator AmperageDCA-125USJ 50 HZ- Gauge Reading How to Read the OutputTerminal GaugesReading Amperage DCA-125USJ 50 HZ- Output Terminal Panel Connections Uvwo Terminal Output Voltages3Ø 220/127 Output Terminal Lug Voltages 3Ø 200V/1Ø115V Output Terminal Lug Voltages3Ø 440/254 Output Terminal Lug Voltages DCA-125USJ 50 HZ- Output Terminal Panel Connections1Ø 200V/100V Output Terminal Lug Voltages DCA-125USJ 50 HZ- PRE-SETUP Circuit BreakersLubrication Oil Fuel CheckDCA-125USJ 50 HZ- PRE-SETUP Refueling ProcedureContact and/or inhaling fumes ALWAYS! place trailer on firm level ground before refuelingCleaning the Radiator Air Cleaner Fan Belt TensionOperation FreezingWeather Must be less than 50%Battery Cable Installation When connecting battery do the followingWiring AlternatorDCA-125USJ 50 HZ- Generator START-UP Procedure Manual Before StartingStarting Manual LED onOil Pressure Gauge DCA-125USJ 50 HZ- Generator START-UP Procedure Auto Mode Starting Auto ModeEmergency Shutdown Procedure DCA-125USJ 50 HZ- Generator SHUT-DOWN ProcedureShutdown Procedure DCA-125USJ 50 HZ- Maintenance Air Removal Check Oil LevelReplacing Oil Filter Replacing Fuel FilterDCA-125USJ 50 HZ Operation and Parts Manual REV. #0 03/11/05 DCA-125USJ 50 HZ-TRAILER Brakes Maintenance Brake AdjustmentBrakes Hydraulic Surge BrakesDCA-125USJ 50 HZ-TRAILER Maintenance Tires/Wheels/Lug NutsTire Wear/Inflation SuspensionLug Nut Torque Requirements DCA-125USJ 50 HZ-TRAILER MaintenanceStart all wheel lug nuts by hand DCA-125USJ 50 HZ-TRAILERWIRING Diagram Trailer/Towing Vehicle Wiring DiagramDCA-125USJ 50 HZ- Generatorwiring Diagram Generator Wiring DiagramDCA-125USJ 50 HZ- Enginewiring Diagram Engine Wiring DiagramDCA-125USJ 50 HZ-TROUBLESHOOTING Generator Generator TroubleshootingDCA-125USJ 50 HZ-TROUBLESHOOTING Engine Controller Engine Controller TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnTo 3 Units Qty DescriptionDCA-125USJ 50 HZ- Generator Assy DCA-125USJ 50 HZ- Generator Assy DCA-125USJ 50 HZ- Control BOX Assy M3213000702 03300001800601808823 LAF3630010393PDCA-125USJ 50 HZ- Control BOX Assy DCA-125USJ 50 HZ- Control BOX Assy DCA-125USJ 50 HZ- Engine and Radiator Assy M3923200054 0602041292RE504836 0602042594Engine & Radiator Assy DCA-125USJ 50 HZ- Engine and Radiator Assy DCA-125USJ 50 HZ- Outputterminal Assy DCA-125USJ 50 HZ- Outputterminal Assy DCA-125USJ 50 HZ- Battery Assy 0602220196 4D-2M9310500404 M9103000504DCA-125USJ 50 HZ- Muffler Assy M3330100402 0017112030M3333000903 M3333200304DCA-125USJ 50 HZ- Fueltank Assy DCA-125USJ 50 HZ- Fuel Tank Assy DCA-125USJ 50 HZ- Enclosure #1 Assy Enclosure #1 AssyM3413001812 M33633003030016910030 0603306797DCA-125USJ 50 HZ- Enclosure #1 Assy 24A M3493200614 24A M34932012040010114040 25A 0030014000DCA-125USJ 50 HZ- Enclosure #2 Assy Enclosure #2 AssyM3443000802 M3443000812M3493303203 M3443000904DCA-125USJ 50 HZ- Rubber Seals Assy 0229200870 02292011300229201240 0228900660DCA-125USJ 50 HZ- Nameplate and Decals Assy M1550000204 M15000020M1550000703 M15000070Terms and Conditions of Sale Parts DCA-125USJ 50 HZ Operation and Parts Manual REV. #0 03/11/05 Your Local Dealer is