3. INSTALLATION

3.1 Preparations

1.If the lawn in the proposed working area is taller than 10 cm, mow it using a normal lawn mower. Then collect the clippings.

2.Read carefully through all the steps before the installation.

3.Check that all parts for the installation are included:

The numbers in brackets refer to the detail diagram 2.1 Automower™, what’s what? on page 11.

• Operator’s Manual (23)

• Automower

Loop generator/charger (18)

Loop wire for the boundary wire (15)

Staples (19)

Connector for the loop wire (20)

Measurement gauge (20)

Solderless coupler for the loop wire (22)

During installation you will also need: A hammer to knock the staples into the ground, combination pliers, and a straight spade if the boundary wire is to be buried.

3.2Installation of the loop generator/charger

The loop generator/charger must be placed where it is well ventilated and is not exposed to direct sunlight. The mower's battery is spared if it is charged in the lowest possible ambient temperature. It is also beneficial if the transformer can be placed under a roof.

Consider the distance to a wall socket when choosing the position. The loop generator/charger must be connected to a 230 V wall socket and there must be room for the mower when it is to charged.

It is recommended to use an earth fault-breaker when connecting the transformer to the wall socket.

3012-756

3012-757

3012-752

English - 17

Image 16
Contents Husqvarna Automower 210 C OPERATOR’S Manual Table of Contents Table of Contents Introduction Safety IntroductionSymbols on Automower Symbols in the Operator’s Manual Safety instructions UseMaintenance TransportPresentation Automower, what’s what? Numbers in the picture correspond toCapacity Function of AutomowerMowing technique 3012-422 Working method One Automower in several gardens Movement patternInstallation Carry out the installation in the following stepsInstallation of the loop generator/charger PreparationsCharging the battery Installation and connecting the loop generator/chargerInstallation of the boundary wire Best position for the boundary wireBoundaries for the working area 30 cm10 cm Boundaries within the working area Secondary areas SlopesLaying out the boundary wire 3012-745 3012-535 Connecting the boundary wire Checking the installation Linking Automower to the loop generator/chargerStarting Automower UseStopping Automower Adjusting the cutting height Switching off AutomowerRestart Changing the PIN code Sounds Sound SignificanceSelect Control panelNumbers Main switch Indicator lampsProposals for installation Garden exampleGarden with steep inclines can be mown Maintenance BatteryService CleaningWinter storage AutomowerDo not use running water when cleaning Underframe and blade discChassis WheelsReplacing the blades Body3012-260 Trouble shooting Fault messagesTrouble Shooting Fault symptom Environmental Information Technical dataData Automower 210 C EU declaration of conformity EU Declaration of Conformity only applies to EuropeEU Declaration of Conformity Index Trouble Shooting Guide symptom 115 03