3. INSTALLATION
Automower can mow areas inside the working area that slope up to 35 cm per distance metre (35 %). Areas that slope more must be demarcated by the boundary wire.
When any part of the working area's boundary slopes more than 10 cm per distance metre (10 %), the boundary wire must be routed about 35 cm in on flat ground before the slope starts.
Laying out the boundary wire
Run the boundary wire around the working area, but wait before connecting the wire to the loop generator/charger.
IMPORTANT INFORMATION
Extra wire must not be placed in coils outside the boundary wire. This can disrupt Automower™.
Tip! Use the supplied measurement gauge as a guide when you lay out the boundary wire. This helps you to easily set the correct distance between the boundary wire and the boundary/obstacle.
If you intend to staple down the boundary wire:
•Tip! Mow the lawn where the wire is to be laid using a normal lawn mower or a trimmer. It will then be easier to lay the wire close to the ground and the risk of the mower cutting the wire off is reduced.
English - 23