Symptom/Error FRU/Action in Sequence
Indicator incorrectly
remains off or on, but
system runs cor-
rectly.
Reconnect the indicator board
connector.
Indicatorboard
Power-Related SymptomsSymptom/Error FRU/Action in Sequence
Power shuts down
during operation.
Go to “Power Systems
Check” on page 25.
ACAdapter
Batterypack
Audio and battery function
connection board
Chargerboard
Systemboard
The system doesn't
power on.
Go to “Power Systems
Check” on page 25.
ACAdapter
Chargerboard
Systemboard
The system doesn't
power off.
Go to “Power Systems
Check” on page 25.
Hold and press the power
switch for more than 4
seconds.
Chargerboard
Systemboard
Battery can't be
charged.
Go to “Power Systems
Check” on page 25.
Batterypack
Chargerboard
Systemboard
Memory-Related SymptomsSymptom/Error FRU/Action in Sequence
Memory count (size)
appears different
from the actual size.
Go to “Memory Check” on
page 27.
Enter BIOS Utility and
execute "Load Setup Default
Settings"; then reboot the
system.
DIMM
Systemboard
42 ThinkPad i Series 1400 HMM