Symptom/Error

 

FRU/Action in

Sequence

 

 

 

 

 

 

 

 

 

 

No

beep

during

Ÿ

Adjust

the audio

volume

 

POST

but

system

 

control.

 

 

runs correctly.

Ÿ

Speaker connector

 

 

 

 

 

 

 

 

 

 

Ÿ

System board

 

 

 

 

 

Note: The

buzzer is

on the

 

 

 

 

 

System board.

 

 

 

 

 

 

 

 

 

 

Keyboard/TrackPoint-Related

Symptoms

Symptom/Error

 

 

FRU/Action

in

Sequence

 

 

 

 

 

 

 

 

 

 

Keyboard

(one

or

Ÿ

Go to “Keyboard and External

more keys) doesn't

 

Input

Device Check”

on

work.

 

 

 

page

28.

 

 

 

 

 

 

Ÿ

Reconnect

keyboard

cables.

 

 

 

Ÿ

Keyboard

 

 

 

 

 

 

Ÿ

System board

 

 

 

 

 

 

 

 

 

 

 

TrackPoint

does

not

Ÿ

Go

to

“TrackPoint IV

Check”

work.

 

 

 

on

page 29.

 

 

 

 

 

Ÿ

Reconnect

keyboard

cables.

 

 

 

Ÿ

TrackPoint board

 

 

 

 

 

Ÿ

Keyboard

 

 

 

 

 

 

Ÿ

System board

 

 

 

 

 

 

 

 

 

 

 

 

LCD-Related Symptoms

LCD FRU Replacement Notice

The TFT

LCD

for

the notebook

computer

contains

 

over 2,359,296 thin-film transistors (TFTs). A small

 

number

of

missing, discolored,

or

lighted dots

(on

the time) is characteristic of TFT LCD technology,

excessive

pixel

problems can

cause

viewing concerns

The LCD should be replaced if the number of miss

discolored,

or

lighted dots

in

any

background

is:

ŸSVGA (12.1"): 5 or more bright dots, 5 or more

dark dots, or a total of 9 or more bright an dots

ŸXGA (13.3"): 8 or more bright dots, 8 or more

dark dots, or a total of 9 or more bright an dots

40 ThinkPad i Series 1400 HMM

Page 48
Image 48
IBM 1400 (2611) Keyboard/TrackPoint-Related Symptoms, LCD-Related Symptoms, LCD FRU Replacement Notice, Tft, Sequence