Installing the VCN Access Concentrator 25

switch user guide. Implement the MAC addresses listed in Table 5 for the VCN AC. Repeat the procedure to define the MAC addresses of the 24 VCN APs attached to the VCN AC. Start with the lowest VCN AP MAC address of 00-C0-DA-40-80-19 and assign addresses for up to 24 VCN APs consecutively.

Manual Procedures for SuperStack II 1100/3300

Enter every one of the 24 VCN AC port MAC addresses through the SuperStack II web management interface.

Refer to the SuperStack® II Switch Management Guide, and follow the instructions in the section “Inserting Permanent Entries” for the Switch Database dialog. You will need to use a web browser on the computer connected to the switch.

Insert the VCN AC port MAC addresses before connecting the VCN AC to the Ethernet switch.

To manually insert a MAC address for an VCN AC port:

1From the Port Filter list box, select a port for the entry. Ignore the VLAN Filter list box.

2In the Enter MAC Address field, enter the MAC (Ethernet) address for the port.

3From the Select Action Type list box, select Insert.

4Click the Apply button.

The Display Database Entries table displays the new entry.

5Repeat steps 1 through 4 for every port.

The Display Database Entries table is not automatically updated with the new entry.

To update the table:

1From the Select Action Type list box, select Display All.

2Click the Apply button.

Table 5 lists the MAC addresses in hexadecimal format.

Page 25
Image 25
3Com DIA3CV1100-02 manual Manual Procedures for SuperStack II 1100/3300