3Com Switch 8800 Configuration Guide Chapter 4 User Interface Configuration
4-2
z VTY is numbered after AUX user interface. The absolute number of the first VTY is
incremented by 1 than the AUX user interface number.

II. Relative number

The relative number is in the format of “user interface type” + “number”. The “number”
refers to the internal number for each user interface type. This method can only specify
one interface or one group of interfaces for a user interface type instead of different
user interface types.
It follows the rules below:
z Number of Console user interface: console 0.
z Number of AUX user interface: AUX 0.
z Number of VTY: The first VTY interface is designated as VTY 0; the second one is
designated as VTY 1, and so on.
4.2 User Interface Configuration
The following sections describe the user interface configuration tasks.
z Entering User Interface View
z Define the Login Header
z Configuring Asynchronous Port Attributes
z Configuring Terminal Attributes
z Managing Users
z Configuring Modem Attributes
z Configuring Redirection

4.2.1 Entering User Interface View

The following command is used for entering a user interface view. You can enter a
single user interface view or multi user interface view to configure one or more user
interfaces respectively.
Perform the following configuration in system view.
Table 4-1 Enter user interface view
Operation Command
Enter a single user interface view or
multi user interface views user-interface [ type ] first-number
[ last-number ]

4.2.2 Define the Login Header

The following command is used for configuring the displayed header when user login.