3Com Switch 8800 Configuration Guide Chapter 46 System Maintenance and Debugging
46-30
kill -HUP 147
After the above operation, the switch system can record information in related log files.
Note:
To configure facility, severity, filter and the file syslog.conf synthetically, you can get
classification in great detail and filter the information.
I. Network requirements
The Network requirements are as follows:
z Sending the log information of the switch to Linux loghost
z The IP address of the loghost is 202.38.1.10
z The information with the severity level above informational will be sent to the
loghost
z The output language is English
z All modules are allowed to output information
II. Network diagram
Switch PC
Network
SwitchSwitch PC
Network
Figure 46-3 Network diagram
III. Configuration procedure
1) Configuration on the switch
Enable info-center
[SW8800] info-center enable
Set the host with the IP address of 202.38.1.10 as the loghost; set the severity level
threshold value as informational, set the output language to English; set all the modules
are allowed output information.
[SW8800] info-center loghost 202.38.1.10 facility local7 language english