Troubleshooting the NJ240FX
If you encounter problems with the IntelliJack:
■Verify the IntelliJack is receiving power by viewing the Power LED (it should be on). If the Power LED is not on, make sure that:
■The local power supply is plugged into the IntelliJack and into a working electrical outlet.
■Verify the IntelliJack is connected to the network properly by viewing the Link LED (it should be on). If the Link LED is not on, make sure the network cable:
■Is terminated properly. Refer to the connector manufacturer’s instructions for terminating the cable. Be sure to test the connector and verify it is working.
■Has a valid connection to the network.
■Adheres to proper length and cabling specifications for your network.
■The IntelliJack is configured for manual MDI. Be sure to use a 
Troubleshooting Matrix
Event/Message | Description | Solution | 
  | 
  | 
  | 
Power LED is not on  | IntelliJack is not receiving  | ■ Ensure power supply is properly  | 
  | power  | connected.  | 
  | 
  | ■ Make sure the upstream switch is  | 
  | 
  | configured and active  | 
  | 
  | 
  | 
Link LED is not on  | IntelliJack has no connection  | ■ Make sure network cable is properly  | 
  | to the network  | terminated.  | 
  | 
  | ■ Make sure the IntelliJack is connected  | 
  | 
  | to the network.  | 
  | 
  | ■ Make sure the cable is plugged into  | 
  | 
  | the workgroup switch.  | 
  | 
  | ■ Make sure the upstream switch is  | 
  | 
  | configured and active  | 
  | 
  | 
  | 
Green LEDs on Ports   | Network device has no  | ■ Make sure the cable is properly  | 
are not on  | connection to IntelliJack  | connected to the network device.  | 
  | 
  | ■ Make sure the cable is firmly  | 
  | 
  | connected to one of the four  | 
  | 
  | IntelliJack ports labeled   | 
  | 
  | ■ Make sure the cable is a good  | 
  | 
  | |
  | 
  | 
  | 
59