Troubleshooting the NJ240FX

Event/Message

Description

Solution

 

 

 

 

Amber LED on Port 1 is

Power is not being

■

Make sure the cable is properly

not on

forwarded to network

 

connected to Port 1 of the IntelliJack.

 

device

■

Make sure the cable is properly

 

 

 

 

 

connected to the powered device.

 

 

■ Make sure the IntelliJack is configured

 

 

 

to match the cable - either straight

 

 

 

through or crossover.

 

 

■ Make sure the powered device is IEEE

 

 

 

802.3af compatible.

 

 

■ Make sure the power requirement for

 

 

 

the powered device does not exceed 7

 

 

 

watts. The IntelliJack can only forward

 

 

 

up to 7 watts.

 

 

 

 

Power LED is blinking

Unit has detected a problem.

■

Contact 3Com Technical Support.

continuously

Traffic can pass through, but

 

 

 

management will not work.

 

 

 

 

 

 

Authentication Failure

Wrong password has been

■

Confirm correct password and re-

 

entered

 

type.

 

 

 

 

Timeout

Device did not respond

■

Refresh the screen after a few

 

within a specified period of

 

seconds. If the problem persists, try to

 

time

 

rediscover the device.

 

 

 

 

Attributes Error

Unexpected configuration

■

Confirm that you have specified valid

 

parameters

 

parameter values and retry the

 

 

 

configuration operation.

 

 

■ NOTE: This error should not appear to

 

 

 

the user under normal conditions.

 

 

 

 

General Error

Something other than

■

Retry the operation you were

 

authentication failure,

 

performing.

 

timeout or attributes error

■

NOTE: This error should not appear to

 

has occurred

 

 

the user under normal conditions.

 

 

 

 

 

 

 

60