13-MAINTENANCE AND REPAIRS (continued)

Remove the locking screws and the protection covers.

Loosen the tensioning screws.

Release the nut of the tensioning plate.

Remove and replace the drive belt.

Important Before setting the new belt, check the wear of the orange plastic rings on the drive pulleys: replace them if they are worn out.

WARNING

To reduce the risk associated with mechanical and electrical hazards:

Turn electrical and air supply off and disconnect before performing any adjustments, maintenance or servicing the machine or taping heads

Figure 13-9

Figure 13-10

Figure 13-11