GLOBAL ADMINISTRATOR SECTION CHAPTER 1: SYSTEM SCREEN

Enable SNMP

The Monitoring mode is “Off” by default. To enable SNMP, click Enable in the Monitoring Mode frame. As a result, all elements in this window become activated.

Specify Monitoring Settings

Set up Community Token for Public Access

Enter the password to be used as the Community token for public access. This is the password that the manage- ment ProxyBlocker console would use when requesting access.

Create, Build the Access Control List

1.In the Enter new IP to add field, enter the IP address of an interface from/to which the SNMP should receive/ send data.

2.Click Add to include the entry in the Access control list box.

Repeat steps 1 and 2 for each IP address to be included in the list.

3.After all entries are made, click Save Changes.

Maintain the Access Control List

1.To remove one or more IP addresses from the list, select each IP address from the Access control list, using the Ctrl key for multiple selections.

2.Click Delete.

3.Click Save Changes.

150

8E6 TECHNOLOGIES, PROXYBLOCKER USER GUIDE

Page 164
Image 164
8e6 Technologies ProxyBlocker manual Enable Snmp, Specify Monitoring Settings, Set up Community Token for Public Access