APPENDICES SECTION APPENDIX F
8E6 TECHNOLOGIES, PROXYBLOCKER USER GUIDE 445

Step 4: Rebuild the hard drive

Once the failed hard drive has been replaced, return to the
Hardware Failure Detection window in the Administrator
console, and click Rebuild to proceed with the rebuild
process.
WARNING: When the RAID array reconstruction process begins,
the Administrator console will close and the hard drive will
become inaccessible.

Step 5: Contact Technical Support

Contact Technical Support to order a new replacement hard
drive and for instructions on returning your failed hard drive
to 8e6.

Power supply failure

Step 1: Identify the failed power supply

The administrator of the server is alerted to a power supply
failure on the chassis by an audible alarm and an amber
power supply LED—or an unlit LED—on the front and rear
of the chassis.
NOTE: A steady amber power supply LED also may indicate a
disconnected or loose power supply cord. Verify that the power
supply cord is plugged in completely before removing a power
supply.
WARNING: Be sure the correct failed power supply has been
identified. Removing the wrong power supply will cause the
system to crash.

Step 2: Unplug the power cord

To prevent electrical shock to yourself and damage to the
unit, unplug the power cord from the failed power supply.