APPENDICES SECTION APPENDIX F

Step 4: Rebuild the hard drive

Once the failed hard drive has been replaced, return to the Hardware Failure Detection window in the Administrator console, and click Rebuild to proceed with the rebuild process.

WARNING: When the RAID array reconstruction process begins, the Administrator console will close and the hard drive will become inaccessible.

Step 5: Contact Technical Support

Contact Technical Support to order a new replacement hard drive and for instructions on returning your failed hard drive to 8e6.

Power supply failure

Step 1: Identify the failed power supply

The administrator of the server is alerted to a power supply failure on the chassis by an audible alarm and an amber power supply LED—or an unlit LED—on the front and rear of the chassis.

NOTE: A steady amber power supply LED also may indicate a disconnected or loose power supply cord. Verify that the power supply cord is plugged in completely before removing a power supply.

WARNING: Be sure the correct failed power supply has been identified. Removing the wrong power supply will cause the system to crash.

Step 2: Unplug the power cord

To prevent electrical shock to yourself and damage to the unit, unplug the power cord from the failed power supply.

8E6 TECHNOLOGIES, PROXYBLOCKER USER GUIDE

445

Page 459
Image 459
8e6 Technologies ProxyBlocker manual Power supply failure, Rebuild the hard drive, Contact Technical Support