Replacing the Thermal Module

IMPORTANT:Apply a suitable thermal grease and ensure all heat pads are in place before replacing the
Thermal Module.
The following thermal grease type s are approved for use:
Silmore GP50
Honeywell PC M4 5F -SP
ShinEtsu 7762
The following thermal pads are approved for use:
Eapus XR-PE
1. Remove all traces of thermal grease from the CPU using a lint-free cloth or cotton swab and Isopropyl
Alcohol, Acetone, or other approved cleaning agen t.
2. Apply a small amount of thermal grease to the centre of the CPU—there is no need to spread the grease
manually, the force used during the installation of the Thermal Module is sufficient.
3. Align the screw holes on the Therma l Module and
Mainboard then replace the module. Keep the
module as level as possible to spread the thermal
grease evenly.
4. Replace the fo u r secu ri ng screw s (in nu me ri ca l
order from screw 1 to screw 4) to secure the
Thermal Module in place.
5. Connect the fan cable to the Mainboard.