RMC 7182

1U Rackmount System

Chassis

Model: SC113MTS-560C (1U Rackmount)

Dimensions: (WxHxD) 17.2 x 1.7 x 20 in. (437 x 43 x 508 mm)

Note: please visit our web site for information on supported operating systems

Weight

Gross Weight: 33 lbs. (15 kg.)

System Cooling

4 x 4-cm high performance fans

System Input Requirements

AC Input Voltage: 100-240V AC auto-range

Rated Input Current: 6.5A (100V) to 2.6A (240V)

Rated Input Frequency: 50 to 60 Hz

Power Supply

Rated Output Power: 560W

Rated Output Voltages: +5V (20A), +3.3V (20A), +12V (46.5A), +5Vsb (4A), -12V (0.5A)

Operating Environment

Operating Temperature: 10º to 35º C (50º to 95º F)

Non-operating Temperature: -40º to 70º C (-40º to 158º F)

Operating Relative Humidity: 8% to 90% (non-condensing)

Non-operating Relative Humidity: 5 to 95% (non-condensing)

Regulatory Compliance

Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/- 3-3, CISPR 22 Class A

Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-

4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)

Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA andCanada), CE Marking (Europe)

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlor- ate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate"

 

© Copyright 2009 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Page 103
Image 103
Acnodes RMC 7182 Chassis, Weight, System Cooling, System Input Requirements, Power Supply, Operating Environment