S3

Command Line Termination Character (user defined)

Range:

0−127, ASCII decimal

Default:

13 (carriage return)

Units:

ASCII

This register determines the ASCII values as the carriage return character. This char- acter is used to end command lines and result codes.

S4

Response Formatting Character (user defined)

Range:

0−127, ASCII decimal

Default:

10 (line feed)

Units:

ASCII

This register determines the ASCII value used as the line feed character. The modem uses a line feed character in command mode when it responds to the computer.

S5

Command Line Editing Character (user defined)

Range:

0−32, 127

Default:

8 (backspace)

Units:

ASCII

This register sets the character recognized as a backspace and pertains to asynchro- nous only. The modem will not recognize the backspace character if it is set to a value that is greater than 32 ASCII. This character can be used to edit a command line. When the echo command is enabled, the modem echoes back to the local DTE the backspace character, an ASCII space character, and a second backspace character. This means a total of three characters are transmitted each time the modem processes the backspace character.

S6

Wait Before Dialing

Range: 2-65

Default: 2

Units:seconds

This register sets the length of time, in seconds, that the modem must wait (pause) after going off-hook before dialing the first digit of the telephone number. The mo- dem always pauses for a minimum of two seconds, even if the value of S6 is less than two seconds. The wait for dial tone call progress feature (W dial modifier in the dial string) will override the value in register S6. This operation, however, may be affected by some ATX options according to country restrictions.

68