B-6
ANA-5910/5930/5940 User’s Guide
E1019 ATMO_SIG: SSCOP (UNI 3.0/
3.1): VT(CC) >= MaxCC
E1020 ATMO_SIG: SSCOP (UNI 3.0/
3.1): Timer_NO_RESPONSE expiry
E1021 ATMO_SIG: SSCOP (UNI 3.0/
3.1): SD, POLL, or SDP N(S) error
E1022 ATMO_SIG: SSCOP (UNI 3.0/
3.1): STAT N(PS) error
E1023 ATMO_SIG: SSCOP (UNI 3.0/
3.1): STAT N(R) or list elements error
E1024 ATMO_SIG: SSCOP (UNI 3.0/
3.1): USTAT N(R) or list elements
error
E1025 ATMO_SIG: SSCF (UNI 3.0
only): Misuse of SSCOP, AA-
RESYNC.ind received
These messages, preceded by E1018,
are for informational purposes. No
action is required.
E1040 ATMO_SIG: Q-93B
GENERAL CONFIG FAILURE
E1041 ATMO_SIG: Q-93B
DATA_LINK CONFIG FAILURE for
PORT variable
E1042 ATMO_SIG: Q-93B SERVICE
LAYER CONFIG FAILURE for PO RT
variable
E1046 ATMO_SIG: Resources
unavailable - out of memory
These errors occur when there is not
enough memory on the system.
Increase the amount of memory.
E1044 ATMO_SIG: Primitive received
with invalid SAP id
This error, while not fatal, indicates
that users are trying to use SVCs
without valid parameters. This
message is useful for debugging when
the Classical IP portion of the driver is
not working.
E1043 ATMO_SIG: SAP down - max
number of RESTARTS sent on PORT
variable
E1045 ATMO_SIG: Virtual channel
(variable) down maximum number of
Restarts sent
These messages indicate that
signalling has encountered problems
with the switch. Stop the driver, then
restart it.
Driver Console Error Message Description