B-9
Windows NT Specific Error Messages and Diagnostics
W1218 ATMO_SIG: SSCOP (UNI 3.1
only): Credit obtained
W1212 ATMO_SIG: SSCOP (UNI 3.0/
3.1): RSAK
W1301 ATMO_SIG: Primitive
(variable) incompatible with SAP state
W1302 ATMO_SIG: Primitive
(variable) unknown
W1303 ATMO_SIG: Primitive
(variable) has invalid parameters
These warning messages are non fatal.
The driver prints them to provide
information. These messages usually
precede error messages.
W1304 ATMO_SIG: Trying to
Reconnect to the switch
This message is printed following
message E1018. The driver is trying to
establish a connection with the switch.
This message is non fatal. Stop the
driver and restart it. If this does not
help call technical support.
W3100 ATMO_DIAG: Adaptec ATM
NIC hardware Diagnostics failed! Run
'aatmdiag' for failure details.
Diagnostics selftest detected a
hardware problem when the
atmo.sys
driver was initially configured using
aatmcnfg
. Run the command line
utility
aatmdiag
for more details on
which diagnostics test failed. See
Diagnostics on page B-11 for
command usage.
W3200 ATMO_DIAG: System
Memory allocation failed. Re-run
command.
Note: Error messages W5101 to
W5430 are used for both
atmo.sys
and
aarp.sys
drivers. The messages
display as WARNING: ACIP W5152
(2,1,2): start up failed
.
Diagnostics attempted to alloc ate
system memory that was not
available. Restart the command line
utility that failed (e.g.,
aatmcnfg.exe
).
If the problem persists, termina te
applications that consume kernel
memory to free up memory space.
W5152 startup failed
The startup procedure failed. Another
message will appear giving the
reason.
W5153 shutdown failed
The shutdown procedure failed.
Another message will appear giving
the reason.
Driver Console Error Message Description