Configure and View Status
2Do the following for each system setting option you want to change:
•Type the number of the option you want to configure.
•Select, using the spacebar, or type the appropriate information for each option as indicated in Table 8 then press
ENTER .
3After you type R or M and have made changes to the ADSL transceiver, you are prompted Save current settings (Y/N)? Type Y for yes or N for no. You then return to the ADSL Menu.
Table 8. ADSL Transceiver Options
Type | For | Function |
|
|
| |
No. | Option |
|
|
|
| |
1 | Startup | Select one of three startup options using the spacebar. The unit |
|
|
| |
|
| Option | uses the option you select to achieve a transmission rate for the |
|
|
|
|
|
| ADSL line at a reboot or if the line is dropped and recovered. |
|
|
|
|
|
| Full startup always - System will always attempt a full startup |
|
|
|
|
|
| where it will set a transmission rate up to the maximum specified |
|
|
|
|
|
| in options 2 and 3 for maximum upstream and downstream data |
|
|
|
|
|
| rate. It determines this rate by assessing the signal quality data |
|
|
|
|
|
| (line length and noise conditions, for example) and the SNR |
|
|
|
|
|
| value set in option 4 for SNR startup margin. It then uses the |
|
|
|
|
|
| highest available rate based on this information. |
|
|
|
|
|
| Session startup - Session startup uses the data acquired during a |
|
|
|
|
|
| full startup to achieve a transmission rate, rather than |
|
|
|
|
|
|
|
|
| |
|
|
| performs a session startup upon every powerup or reset and |
|
|
|
|
|
| would also revert back to a full startup attempt when a session |
|
|
|
|
|
| startup is not successful for 30 seconds. This is the default. |
|
|
|
|
|
| Fixed data rate - At startup, the system attempts only the data |
|
|
|
|
|
| rates that you select in options 2 and 3 for maximum upstream |
|
|
|
|
|
| and downstream data rates. The system attempts to come up at |
|
|
|
|
|
| the programmed data rates with a margin greater than or equal to |
|
|
|
|
|
| the configured margin. If the data rates cannot be obtained, then |
|
|
|
|
|
| the system will continue to attempt the data rate. If it does not |
|
|
|
|
|
| achieve it, sync will not occur. |
|
|
|
|
|
|
|
|
| |
2* | Max Up | Select a maximum data rate for the upstream channel (from |
|
|
| |
|
| Data | subscriber to service provider). Use the spacebar to scroll |
|
|
|
|
| Rate | through the available rates. |
|
|
|
|
|
| (continued) |
|
|
|
|
|
|
|
| ||
| Megabit Modem | 27 |