INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

Gas Connection

Installation of this range MUST conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-latest edition.

In Canada

The range MUST be installed in accordance with the current CGA Standard CAN/CGA-B149 – Installation Codes for Gas Burning Appliances and Equipment and/or local codes.

In The Commonwealth Of Massachusetts

When installed within the Commonwealth of Massachusetts this product MUST be installed by a licensed plumber or gas fitter.

Fig.7-27

16” (41cm)

2.5” (6.5cm)

Area accessible through the drawer cavity with the drawer removed.

Area approx 17” (431mm) x 5¾” (146mm)

A ‘T’ handle type manual gas valve MUST be installed in the gas supply line to this appliance.

Gas Supply Requirements

The recommended gas pipe outlet locations are shown in Fig.7-27, Fig.7-28and Fig.7-29.

Provide Adequate Gas Supply

Before installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment of the appliance are compatible.

The range is designed to operate at a manifold pressure of 4’’ of water column (1 kPa) on natural gas. A conversion kit for LP gas (Propane) is supplied with the range. When converted to LP gas, a pressure of 10’’ of water column (2.49 kPa) is required.

Make sure you are supplying your range with the correct type of gas.

If the range is to be used on LP gas a qualified LP installer MUST convert it. We recommend that the range be converted before installation. This must be done before the range can be used on LP gas.

For proper operation the pressure of natural gas supplied to the regulator must be between 4½’’ and 13’’ of water column (1.12–3.24 kPa).

For LP gas, the pressure supplied must be between 10’’ and 13’’ of water column (2.49–3.24 kPa).

When checking for proper operation of the regulator, the inlet pressure must be at least 1’’ (0.25 kPa) greater than the operating (manifold) pressure as given above.

The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used.

A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of ½’’ and be 5’ in length for ease of installation.

Fig.7-28

ArtNo280-0074 Connection fron Rear

ArtNo.280-0075 - Opening inside the drawer

Fig.7-29

10¼” (26cm) 7¾” (19.7cm)

6“ (15.2cm) from the floor

8¾” (22.2cm) from with range at lowest point the side of the range

33

Page 35