INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.

36

Moving the Range for Servicing
Follow these procedures to remove appliance for servicing:
Shut o the gas supply and turn o the circuit breaker.
Disconnect gas supply tubing to the appliance and unplug
the electrical supply cord.
Note: A suitably qualied person should disconnect and
reconnect the gas supply.
The range is very heavy, so take great care. We recommend
two people maneuver the range. Ensure that the oor
covering is rmly attached, or removed to prevent it being
disturbed when moving the range around. You will need the
leveling tool.
Before attempting to move the range, see ‘Moving the range’
on page 27.

Retting the Range

Reverse the above procedure to ret. If the gas line has been
disconnected, check for gas leaks after reconnection.
Note: A suitably qualied person should disconnect and
reconnect the gas supply.
The service engineer MUST follow the installation instructions
provided with the gas appliance connector and the warning
label attached to the connector.
If the range is removed for any reason, make sure that the
anti-tip device is re-engaged properly when the range
is replaced. Failure to take this precaution could result in
tipping of the range and may cause injury.
Range Operational Checks

Oven Check

Turn on the oven and check that the oven fans start to turn
and that the oven starts to heat up. Turn o the oven.

Oven Light Check

Press the oven light switch and check that the lights are
working.
Note: The oven light bulbs are not included in the warranty.

Ignition of the Cooktop Burners Check

Operation of all cooktop burners should be checked after the
range and gas supply lines have been carefully checked for
leaks.
Check each burner in turn. There is a ame safety device that
stops the ow of gas to the burner if the ame goes out.
There is also a spark ignition system that works when the
knob is pressed in.
For each burner, push in and turn a knob to the lighting
position.
The igniter should spark and light the gas. Keep holding the
knob pressed in to let the gas through to the burner for few
seconds.
If, when you let go of the control knob, the burner goes out,
the safety device has not held in. Turn the control to the
o position and wait one minute, then try again this time
holding in the control knob for slightly longer.

Quality of Flames

If the ame is distorted, check that the burner head is
correctly placed over the burner base.

MAKE SURE THE FLOW OF COMBUSTION AND
VENTILATION AIR TO THE RANGE IS UNOBSTRUCTED.

MAKE SURE ALL CONTROLS ARE LEFT IN THE OFF
POSITION.
Customer Care
Please complete your details in this Guide, inform the user
how to operate the range and hand over the Instructions.
Thank you