INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Range Operational Checks
Oven Check
Turn on the oven and check that the oven fans start to turn and that the oven starts to heat up. Turn off the oven.
Oven Light Check
Press the oven light switch and check that the lights are working.
Note: The oven light bulbs are not included in the warranty.
Ignition of the Cooktop Burners Check
Operation of all cooktop burners should be checked after the range and gas supply lines have been carefully checked for leaks.
Check each burner in turn. There is a flame safety device that stops the flow of gas to the burner if the flame goes out. There is also a spark ignition system that works when the knob is pressed in.
For each burner, push in and turn a knob to the lighting position.
The igniter should spark and light the gas. Keep holding the knob pressed in to let the gas through to the burner for few seconds.
If, when you let go of the control knob, the burner goes out, the safety device has not held in. Turn the control to the off position and wait one minute, then try again this time holding in the control knob for slightly longer.
Quality of Flames
If the flame is distorted, check that the burner head is correctly placed over the burner base.
MAKE SURE THE FLOW OF COMBUSTION AND VENTILATION AIR TO THE RANGE IS UNOBSTRUCTED.
MAKE SURE ALL CONTROLS ARE LEFT IN THE OFF POSITION.
Customer Care
Please complete your details in this Guide, inform the user how to operate the range and hand over the Instructions.
Thank you
Moving the Range for Servicing
Follow these procedures to remove appliance for servicing:
Shut off the gas supply and turn off the circuit breaker. Disconnect gas supply tubing to the appliance and unplug the electrical supply cord.
Note: A suitably qualified person should disconnect and reconnect the gas supply.
The range is very heavy, so take great care. We recommend two people maneuver the range. Ensure that the floor covering is firmly attached, or removed to prevent it being disturbed when moving the range around. You will need the leveling tool.
Before attempting to move the range, see ‘Moving the range’ on page 27.
Refitting the Range
Reverse the above procedure to refit. If the gas line has been disconnected, check for gas leaks after reconnection.
Note: A suitably qualified person should disconnect and reconnect the gas supply.
The service engineer MUST follow the installation instructions provided with the gas appliance connector and the warning label attached to the connector.
If the range is removed for any reason, make sure that the
36