INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

4-Wire Conduit Installation

Fig.7-18

Disconnect the supplied power cord from the terminal block

and ground post. Keep the terminal block parts; you will need them. Remove the strain relief clamp from the power cord

and remove the power cord and strain relief clamp from the mounting bracket (Fig.7-18).

The range is shipped with reducer plates to give a 11/8’’

diameter opening for conduit connection. Find the reducer0040 4 Wire Conduit Fitting plates (Fig.7-19)in the conversion kit and fix them to the

mounting bracket.

Attach a squeeze connector (not supplied with the range), to your conduit. Insert the conduit through the reducer plates on the mounting bracket. Allow enough slack to easily attach the wires to the terminal block.

Note: DO NOT install the conduit without a squeeze connector.

Fig.7-19

ArtNo.280-0039 Reducer Plate

Attach the wires to the ground post and terminal block (Fig.7-20).

Note: Make sure the wires are completely inserted into the terminals and secure connections are made.

Secure the squeeze connector in place in the bracket by tightening the squeeze connector screws.

Replace the electrical connection cover.

ArtNo.280-0081 - 4 Wire conduit terminal connection

Black

Fig.7-20

Red

Installing a 3-Wire Power Cord

Disconnect the supplied power cord from the terminal block and ground post. Keep the terminal block parts; you will need them. Remove the strain relief clamp from the power cord and remove the power cord and strain relief clamp from the mounting bracket. Discard the strain relief clamp.

Note: DO NOT install the power cord without a strain relief

– use the clamp supplied with the cord.

White

Green

Ground

Fig.7-21

Install the new strain relief device to the mounting bracket by removing the two clamping screws, feeding the two halves (ears first) through the hole in the mounting bracket and loosely replacing the screws. Insert the power cord through the strain relief device but do not tighten the device yet (Fig.7-21).

A ground strap is supplied in the conversion pack (Fig.7-22).

Attach the ground strap to the ground and center terminal of the connector block (Fig.7-23).

The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the connector block. The power leads must be connected to the outside terminals.

Make sure the connections are tight. Now tighten the strain relief device to clamp the power cord.

Refit the electrical connection cover.

ArtNo.280-0042 Ground Strap

Fig.7-22

 

Fig.7-23

BlackArtNo.280-0082 - 3-Wire conduit connection‘Ground strap’

White

 

Red

Strain relief

 

device

Ground

31

Page 33
Image 33