*RCL

Meaning and Type

Recall Device State

Recalling a previously stored state may place hazardous voltage at the power module output.

Description

This command restores the power module to a state that was previously stored in memory with a *SAV command to the specified location. The following states are recalled:

CAL:AUTO

LIST:COUN

OUTP:REL[:STAT]

TRIG:LINK

CURR[:LEV][:IMM]

LIST:STEP

OUTP:REL:POL

TRIG:SOUR

CURR:MODE

OUTP[:STAT]

OUTP:TTLT[:STAT]

VOLT[:LEV][IMM]

CURR:PROT:STAT

OUTP:DFI[:STAT]

OUTP:TTLT:LINK

VOLT:MODE

DISP:STAT

OUTP:DFI:LINK

OUTP:TTLT:SOUR

VOLT:PROT[:LEV]

INIT:CONT

OUTP:PROT:DEL

TRIG:DEL

 

Sending *RCL also does the following:

Forces an ABORt command before resetting any parameters (this cancels any uncompleted trigger actions).

Disables the calibration function by setting CAL:STATe to OFF.

The device state stored in location 0 is automatically recalled at power turn-on when the power module configuration switch is set for this mode of operation (see the power module User’s Guide).

Note

Whenever the power module is powered up, the state stored in location 0 is written to the 5 volatile

 

locations (5 through 9).

 

 

 

 

 

Command Syntax

*RCL <NRf>

 

Parameters

0 through 9

 

Example

*RCL 3

 

Query Syntax

(None)

 

Related Commands

*PSC *RST *SAV

*RST

Meaning and Type

Reset Device State

Description

This command resets the power module to a factory-defined state as defined below. *RST also forces an ABORt command.

COMMAND

STATE

 

COMMAND

STATE

 

COMMAND

STATE

CAL:AUTO

OFF

 

OUTP[:STAT]

OFF

 

OUTP.TTLT:LINK

OFF

CAL:STAT

OFF

 

OUTP:DFI

OFF

 

TRIG:DEL

0

CURR[:LEV][:IMM]

1

 

OUTP:DFI:SOUR

LINK

 

TRIG:LINK

OFF

 

 

 

CURR:PROT:STAT

OFF

 

OUTP:DFI:LINK

“SUM3”

 

TRIG:SOUR

BUS

CURR:MODE

FIX

 

OUTP:PROT:DEL

1

 

VOLT[:LEV][:IMM]

0

 

 

 

DISP[:WIND]:STAT

ON

 

OUTP:REL[:STAT]

OFF

 

VOLT:MODE

FIX

INIT:CONT

OFF

 

OUTP:REL:POL

NORM

 

VOLT:PROT:LEV

MAX

LIST:STEP

A UTO

 

OUTP:TTLT[STAT]

OFF

 

1Model-dependent value. See

 

LIST:COUN

1

 

OUTP:TTLT:SOUR

BUS

 

Table 3-2.

 

 

 

 

 

28 Language Dictionary

Page 27
Image 27
Agilent Technologies 66lxxA manual Rcl, Rst