Language Dictionary 49
Query Syntax [SOURce]:VOLTage:PROTection [:LEVel]?
[SOURce]:VOLTage:PROTection [:LEVel]? MIN
[SOURce]:VOLTage:PROTection [:LEVel]? MAX
Returned Parameters <NR3> VOLT:PROT? returns presently programmed OVP level.
VOLT:PROT? MAX and VOLT:PROT? MIN return the
maximum and minimum programmable OVP levels.
Related Commands OUTP:PROT:CLE *RST *SAV *RCL
VOLT:SENS:SOUR?
This command reads the state of the power module output connector remote sense switch. The INTernal parameter
corresponds to the LOCAL position of the switch. (See the power module User’s Guide for more information about this
switch.) VOLT:SENS:SOUR is an alias for the SCPI VOLT:ALC:SOUR command.
Query Syntax [SOURce]:VOLTage:SENSe:SOURce?
Example VOLT:SENS:SOUR?
Returned Parameters EXTernal | INTernal
Related Commands VOLT:ALC:SOUR?
VOLT:TRIG
This command programs the pending triggered voltage level of the power module. The pending triggered voltage level is a
stored value that is transferred to the output terminals when a trigger occurs. A pending triggered level is unaffected by
subsequent VOLT:LEV[:IMM] commands and remains in effect until the trigger subsystem receives a trigger or an
ABORt command is given. In order for VOLT:TRIG to be executed, the trigger subsystem must be initiated (see
INITiate).
Command Syntax [SOURce]:VOLTage[:LEVel]:TRIGgered [:AMPLitude] <NRf+>
Parameters See Table 3-2
Default Suffix V
*RST Value See Table 3-2
Examples VOLT:TRIG 1200 MV VOLT:LEV:TRIG 1.2
Query Syntax [SOURce]:VOLTage[:LEVel]:TRIGgered [:AMPLitude]?
[SOURce]:VOLTage[LEVel]:TRIGgered [:AMPLitude]? MAX
[SOURce]:VOLTage[:LEVel]:TRIGgered [:AMPLitude]? MIN
Returned Parameters <NR3> VOLT:TRIG? returns the presently programmed current
level. If the TRIG level is not programmed, the IMM level is returned.
VOLT:TRIG? MAX and VOLT:TRIG? MIN return the
maximum and minimum programmable triggered voltage levels.
Related Commands ABOR VOLT[:IMM] VOLT:MODE INIT *RST