LIST:CURR:POIN?

This query returns the number of points specified in LIST:CURR. Note that it returns only the total number of points, not the point values.

Query Syntax

[SOURce]:LIST:CURRent:POINts?

Returned Parameters

<NR1>

Example

LIST:CURR:POIN?

Related Commands

CURR:MODE LIST:CURR LIST:DWEL

LIST:DWEL

This command sets the dwell points for the output current list and output voltage list. Each dwell point specifies the time, in seconds, that the output of the power module is to remain at the level specified by the corresponding point in the current or voltage list. At the end of the dwell time, the output of the power module depends upon the following conditions:

If LIST:STEP AUTO has been programmed, the output automatically changes to the next point in the list.

If LIST:STEP ONCE has been programmed, the output remains at the present level until a trigger sequences the next point in the list.

Command Syntax

[SOURce]:LIST:DWEL1 <NRf+> {,<NRf+>}

Parameters

0.01 to 65 MINimum MAXimum

Default Suffix

S

 

Examples

LIST:DWEL .5,.5,1.5

Query Syntax

(None)

 

Related Commands

CURR:MODE

LIST:COUN LIST:CURR LIST:STEP

 

LIST:VOLT

VOLT:MODE

LIST:DWEL:POIN?

This query returns the number of points specified in LIST:DWEL. Note that it returns only the total number of points, not the point values.

Query Syntax

[SOURce]:LIST:DWFL1:POINts?

Returned Parameters

<NR1>

Example

LIST:DWEL:POIN?

Related Commands

LIST:CURR LIST:DWEL LIST:VOLT

LIST:STEP

This command specifies how list sequencing occurs in response to triggers. If LIST:STEP AUTO is sent, then a single trigger causes the list (voltage, current, or dwell) to sequence through all its points. The time that a list remains at each point is as specified in the dwell list. As soon as the dwell interval expires, the list moves to the next point.

If LIST:STEP ONCE is sent, then a single trigger advances a list only one point. After the specified dwell interval, the list remains at that point until the next trigger occurs.

In either mode, triggers that occur during a dwell interval are ignored.

Command Syntax

[SOURce]:LIST:STEP <CRD>

Parameters

AUTO ONCE

*RST Value

AUTO

 

Examples

LIST:STEP ONCE

Query Syntax

[SOURce]:LIST:STEP?

Returned Parameters

AUTO ONCE

Related Commands

CURR:MODE

LIST:COUN LIST:CURR LIST:DWEL

 

LIST:VOLT

VOLT:MODE

38 Language Dictionary

Page 37
Image 37
Agilent Technologies 66lxxA manual Listcurrpoin?, Listdwelpoin?, Liststep Once