6 – Language Dictionary

TRIGger:ACQuire:SOURce

This command selects the trigger source for the measurement trigger system.

EXT

External trigger input signal

BUS

GPIB device, *TRG, or <GET> (Group Execute Trigger)

 

Command Syntax

TRIGger:ACQuire:SOURce <source>

 

Parameters

BUS EXTernal

 

*RST Value

BUS

 

Examples

TRIG:ACQ:SOUR EXT

 

Query Syntax

TRIGger:ACQuire:SOURce?

 

Returned Parameters

<CRD>

TRIGger[:TRANsient]:SOURce

This command selects the trigger source for the output trigger system.

EXTernal

External trigger input signal

BUS

GPIB device, *TRG, or <GET> (Group Execute Trigger)

Command Syntax

TRIGger[:TRANsient]:SOURce <source>

 

Parameters

BUS EXTernal

 

*RST Value

BUS

 

Examples

TRIG:SOUR EXT

 

Query Syntax

TRIGger[:TRANsient]:SOURce?

Returned Parameters

<CRD>

TRIGger[:TRANsient]

This command generates an output trigger. Output triggers affect the following functions: voltage, current, and current limit. To program an output trigger you must specify a trigger level for the selected function, set the selected function to STEP mode, and initiate the trigger system.

Once these conditions are met, the output trigger will:

1.Initiate a pending level change as specified by [SOURce;]CURRent:TRIGgered, [SOURce;]CURRent:LIMit:TRIGgered, or [SOURce;]VOLTage:TRIGgered.

2.Clear the WTG bit in the Status Operation Condition register after both transient and acquire trigger sequences have completed. (WTG is the logical-or of both transient and acquire sequences.)

Command Syntax

TRIGger[:TRANsient][:IMMediate]

Parameters

None

 

Examples

TRIG

TRIG:IMM

Related Commands

ABOR INIT *TRG VOLT:TRIG CURR:TRIG

 

CURR:LIM:TRIG

CURR:MODE CURR:LIM:MODE

 

VOLT:MODE

 

74

Page 74
Image 74
Agilent Technologies N3280A manual TRIGgerACQuireSOURce, TRIGgerTRANsientSOURce, RST Value, Returned Parameters