Specifications - A

 

Table A-2 Supplemental Characteristics (continued)

 

Parameter

 

Voltage Priority

Current Priority

Programming Output

Voltage11 (90% to 10%

150∝s

N/A

Fall Time

+Curr Lim12

@10kHz):

450∝s

N/A

 

(90% to 10%):

450∝s

N/A

 

-Curr Lim13

(90% to 10%):

N/A

160∝s

Current14 (-80% to +80%):

Maximum Output

Lead R:

 

1Ω

 

 

 

 

Cable Impedance

Lead L:

 

10∝H

 

 

100H

 

Overvoltage Protection

Positive:

 

+11.5V

±0.3V

 

N/A

 

15

Negative:

 

-11.5V

±0.3V

 

 

 

 

 

 

 

 

Output Common Mode

(shorting either Hi or Low

 

 

 

<2∝A rms

 

 

Current 16

terminal to the chassis)

 

 

 

 

 

 

 

Trigger in

 

 

Chassis ground referenced TTL levels.

 

Trigger latency

 

 

 

 

30∝s maximum

 

 

GPIB Interface

 

 

 

 

AH1, C0, DC1, DT1, E1,

 

 

Capabilities

 

 

 

L4, PP0, RL1, SH1, SR1, T6

 

Output Derating

 

 

 

 

Full current to 40° C.

 

 

 

 

 

Linearly derated to 50% of full current at 55° C.

 

Output Disconnect

 

 

Accomplished via solid state disconnect relays.

 

 

 

Output impedance in open state is approximately 100K

Altitude Derating

Up to 7500 feet:

 

 

 

Full current @40° C.

 

 

 

> 7500 feet up to 15000

Derated by 1.1 degrees C for every additional 1000 feet

 

feet:

 

 

 

 

 

 

 

Secondary Isolation

To Chassis:

 

 

 

±50V

 

 

 

Output to Output:

 

 

 

±100V

 

 

RFI

 

 

 

 

Level A

 

 

Safety

 

 

 

 

UL, CSA, CE

 

 

Regulatory Compliance

Listing pending:

 

 

 

UL 3111-1

 

 

 

Certified to:

 

 

 

CSA 22.2 No. 1010.1

 

 

 

Conforms to:

 

 

 

IEC 1010-1, EN 61010-1

 

 

 

Complies with:

EMC directive 89/336/EEC (ISM group 1 Class A)

 

Calibration Interval

 

 

 

 

1 Year

 

 

Dimensions

Height:

 

 

 

3.5” (88.9 mm)

 

 

 

Width:

 

 

 

8 3/8” (212.7 mm)

 

 

 

Depth:

 

 

 

19.6” (497.8 mm)

 

 

Weight

Shipping:

 

 

 

26 lbs

(11.8 kg)

 

 

 

Net:

 

 

 

22 lbs

(10 kg)

 

 

Input

 

RMS Input

 

Peak Inrush

Full Load

 

Current

 

current

Input Power

Voltage Range

Line Fuse

Typ.

Max.

Typ.

Max.

Typ.

Max.

100 Vac (87-106 Vac):

3.15AT

1.75A

1.85A

56A

60A

130W

140W

120 Vac (104-127 Vac):

3.15AT

1.4A

1.55A

48A

53A

130W

140W

220 Vac (191-233 Vac):

1.6AT

0.8A

0.90A

34A

40A

130W

140W

230 Vac (207-253 Vac):

1.6AT

0.7A

0.80A

32A

36A

130W

140W

11With no load and current limit set to +0.5125A, program voltage from ±10V to 0V.

12With 20 ohm load resistor and voltage set to 10.25V, program current limit from 0.5A to 0A.

13With 20 ohm load resistor and voltage set to –10.25V program current limit from 0.5A to 0A.

14With 1k load resistor, program current from +0.5mA to –0.5mA. Measure time from +0.4mA to –0.4mA.

15Output is shut down and output relays are opened

16Measurement taken with ammeter having approx. 1k shunt resistance and 10Hz to 1kHz bandwidth. Input ac is 120V, 60Hz.

81

Page 81
Image 81
Agilent Technologies N3280A Fall Time, Maximum Output, Cable Impedance, Overvoltage Protection, Output Common Mode, Safety