Advanced Applications - Chapter 6

Each Local GeneratorÕs pages differ from page 5. Each Local Generator typeÕs parameters are explaned in the chart below:

Generator Type

Page

Display

Description

Envelope

5

Env Trigger Source:

Input which the

 

 

Left/Right/L&R

Envelope looks at for

 

 

 

Modulation cues

 

6

Env Attack Threshold:

Level which triggers the

 

 

-32Ð0dB

Envelope to begin

 

 

 

Modulating

 

7

Env Release Threshold:

Level below which the

 

 

-48Ð0dB

Envelope will stop

 

 

 

Modulating and start to

 

 

 

decay

 

8

Env Attack: 0.00-10.00,

Time which the

 

 

Env Release: 0.00-10.00

Envelope takes to ramp

 

 

Seconds

up to its peak value

 

 

 

after the Attack

 

 

 

Threshold has been

 

 

 

passed, and the time it

 

 

 

takes to ramp down to

 

 

 

zero after the release

 

 

 

threshold has been

 

 

 

passed.

 

9

Env Hold Time: 0.00-

The amount of time that

 

 

10.00 Seconds

the Envelope will hold

 

 

 

at peak value before the

 

 

 

release segment after

 

 

 

the release threshold

 

 

 

has been passed.

Peak Follower

5

Peak Follower Source:

Input which the Peak

 

 

Left/Right/L&R

Follower looks at for

 

 

 

Modulation cues

 

6

Peak Follower Gain: x1-

Amount of gain for the

 

 

x99

input before the Peak

 

 

 

Follower looks at its

 

 

 

signal (for low level

 

 

 

signals)

 

7

Peak Folw. Decay: 0.20-

After the Generator is

 

 

10.00 Seconds

triggered, this is the

 

 

 

rate of the decay

Ramp

5

Ramp Trigger Source:

Input which the Ramp

 

 

Left/Right/L&R

looks at for Modulation

 

 

 

cues

 

6

Ramp Atk. Threshold:

This is the level which

 

 

-40Ð0dB

triggers the Ramp to

 

 

 

begin Modulating

 

7

Ramp Rise Time: 0.00Ð

This is the rate which

 

 

10.0 Seconds

the Ramp will rise to its

 

 

 

peak value

Q20 Reference Manual