Chapter 6 - Advanced Applications
Selecting Banks via MIDI
You can use MIDI Controller 0 messages to select one of the three Program Banks (Preset, User 0 or User 1).
Controller 0 messages (like all controllers) can have a value between 0 and 127; however, a value of 0 will select the Preset Bank, a value of 1 will select the User 0 Bank, and values from 2 to 127 will select the User 1 Bank. If a Controller 0 message is received followed by a Program change message, the QuadraVerb 2 will respond by selecting the appropriate Program number in the appropriate Bank.
Note: Controller 0 messages will change Banks only if the Program Change Table is not being used (MIDI Mode, Page 2).
Program Change Table
Alternatively, you can use a Program Change Table in the Q20 which
To incorporate and modify the Program Change Table:
➀Press [MIDI].
The [MIDI] LED will light.
➁Press [PAGE >] to access MIDI Page 2. The display will read:
MIDI PROGRAM CHANGE: ON
➂Turn the [VALUE/ENTER] knob to the right to set the MIDI Program Change parameter to ÒTABLEÓ.
MIDI PROGRAM CHANGE: TABLE
➃Press [PAGE >] to access MIDI Page 3.
You can edit the program change table, which can substitute alternate Programs (Preset
PROGRAM TABLE: 000 =
88 | Q20 Reference Manual |