Section 3 Troubleshooting
1.The
Is
the main NO power circuit
breaker
on?
YES
1
Is there
voltageNO
into the control
transformer?
YES
Turn on the main power circuit breaker.
Check the wiring between the main power block and the control transformer. Repair or replace the wiring as needed.
| 2 | |
Is there |
| |
voltage | NO | |
out of the | Replace the control transformer. | |
control |
| |
transformer? |
| |
YES |
| |
| 3 | |
Is there |
| |
voltage (120 | NO | |
Volts) into | Replace the 3.15 Amp fuse. | |
and out of the | ||
|
3.15Amp
fuse?
YES
Is there | 4 |
| |
voltage (120 | NO | Reset and return (either by pulling or by | |
Volts) into and | twisting and pulling) the | ||
| |||
out of both sides of |
| If, after resetting and returning, there is | |
the |
| still no voltage, replace the | |
switch? |
| switch. | |
|
|
|
YES
|
| Is there | 5 |
|
|
| |
|
| voltage (220 |
|
|
| Volts) between the | NO |
|
| L2 (blue) and L1 (brown) |
|
|
| wires going into the |
|
|
| power connector |
|
|
| on the main |
|
|
| board? |
|
|
| YES |
|
|
| Is the | 6 |
|
| 125 mA fuse |
|
| YES | below the power | NO |
| connector on the | ||
Replace the 125 mA fuse. |
| main board blown? |
|
| An ohms test is the |
| |
|
|
| |
|
|
| |
|
| recommended |
|
|
| check for |
|
|
| the fuse. |
|
Check the L2 (blue) and L1 (brown) wires between the
Check the cable between the main board and the keypad for any loose or broken connections. Repair or replace the cable as needed.
7
If the cable is intact, please contact Alliance Laundry Systems’ customer service department before replacing the main board, keypad or cable between the main board and keypad.
CFD2S