Section 3 Troubleshooting

1. WE-8 CONTROL HAS NO VISIBLE DISPLAY (P AND N-VOLTAGE MODELS)

The WE-8 control has no visible display.

Is

the main NO power circuit

breaker

on?

YES

1

Is there

voltageNO (380-480 Volts)

into the control

transformer?

YES

Turn on the main power circuit breaker.

Check the wiring between the main power block and the control transformer. Repair or replace the wiring as needed.

 

2

Is there

 

voltage

NO

(200-240 Volts)

out of the

Replace the control transformer.

control

 

transformer?

 

YES

 

 

3

Is there

 

voltage (120

NO

Volts) into

Replace the 3.15 Amp fuse.

and out of the

 

3.15Amp

fuse?

YES

Is there

4

 

voltage (120

NO

Reset and return (either by pulling or by

Volts) into and

twisting and pulling) the E-stop switch.

 

out of both sides of

 

If, after resetting and returning, there is

the E-stop

 

still no voltage, replace the E-stop

switch?

 

switch.

 

 

 

YES

 

 

Is there

5

 

 

 

 

 

voltage (220

 

 

 

Volts) between the

NO

 

 

L2 (blue) and L1 (brown)

 

 

 

wires going into the

 

 

 

power connector

 

 

 

on the main

 

 

 

board?

 

 

 

YES

 

 

 

Is the

6

 

 

125 mA fuse

 

 

YES

below the power

NO

 

connector on the

Replace the 125 mA fuse.

 

main board blown?

 

 

An ohms test is the

 

 

 

 

 

 

 

 

 

recommended

 

 

 

check for

 

 

 

the fuse.

 

Check the L2 (blue) and L1 (brown) wires between the E-stop switch and the power connector on the main board. Repair or replace the wires as needed.

Check the cable between the main board and the keypad for any loose or broken connections. Repair or replace the cable as needed.

7

If the cable is intact, please contact Alliance Laundry Systems’ customer service department before replacing the main board, keypad or cable between the main board and keypad.