Section 4 Service Procedures
WARNING
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
•Disconnect electrical power to the
•Close the gas
•Never start the
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the
W461R1
Refer to Figure 6.
REMOVAL
a.Turn off power to the machine.
b.Remove the top cover. Refer to Paragraph 19.
c.Disconnect the wires from the keymode switch.
d.Using a 5 mm nut driver, remove the nuts that attach the keymode switch to the control panel.
e.Separate the keymode switch from the keymode base and remove them.
INSTALLATION
a.Position the keymode base and keymode switch and connect them.
b.Using a 5 mm nut driver, replace the nuts that attach the keymode switch to the control panel.
c.Reconnect the wires to the keymode switch.
d.Replace the top cover. Refer to Paragraph 19.
e.Turn on power to the machine.
Keymode Control
Base Panel
CFD11S
Keymode
Switch
Figure 6
9001900 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 69 |