| Section 4 Service Procedures |
|
|
|
|
|
|
|
| Cycle 39 — Test Program |
|
|
|
|
|
|
Step | Description | Min:sec | Step Definition | Corrective Action |
|
|
|
|
|
1 | Cold Fill to | 0:30 | The machine should fill with cold water to | Refer to the “Machine Did Not Fill Alarm |
| High Level |
| high level within 30 seconds and, when it | Analysis” flowchart. |
|
|
| does, a buzzer will sound. |
|
|
|
|
|
|
2 | Drain 1 | 0:10 | The machine should drain within 10 seconds | Refer to the “Empty Alarm Analysis” |
|
|
| and, when it does, a buzzer will sound. | flowchart. |
|
|
|
|
|
3 | Hot Fill to Low | 5:00 | The machine should fill with hot water to low | Refer to the “Machine Did Not Fill Alarm |
| Level |
| level within 5 minutes and, when it does, a | Analysis” flowchart. |
|
|
| buzzer will sound. |
|
|
|
|
|
|
4 | Auxiliary Fill | 5:00 | The machine should fill with water to | Refer to the “Machine Did Not Fill Alarm |
| to Medium |
| medium level within 5 minutes and, when it | Analysis” flowchart. |
| Level |
| does, a buzzer will sound. |
|
|
|
|
|
|
5 | Heat (150°F) | 1h00 | This step is needed only if the machine is | Check the components used for the |
|
|
| equipped with auxiliary heat (e.g., steam or | auxiliary heating (e.g., steam valve or |
|
|
| electric heating). If the temperature isn’t | heating elements). |
|
|
| reached within the time programmed, an |
|
|
|
| alarm will sound. |
|
|
|
|
|
|
6 | Cold Fill to | 0:30 | The machine should fill with cold water to | Refer to the “Machine Did Not Fill Alarm |
| High Level |
| high level within 30 seconds and, when it | Analysis” flowchart. |
|
|
| does, a buzzer will sound. |
|
|
|
|
|
|
7 | Supply 1 | 0:30 | Supply compartment A should flush for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
8 | Supply 2 | 0:30 | Supply compartment B should flush for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
9 | Supply 3 | 0:30 | Supply compartment C should flush for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
10 | Supply 4 | 0:30 | Supply relay 1 should be activated for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
11 | Supply 5 | 0:30 | Supply relay 2 should be activated for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
12 | Supply 6 | 0:30 | Supply relay 3 should be activated for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
13 | Supply 7 | 0:30 | Supply relay 4 should be activated for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
14 | Supply 8 | 0:30 | Supply relay 5 should be activated for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
15 | Supply 9 | 0:30 | Supply relay 6 should be activated for 30 | Refer to the “No Fill Analysis” flowchart. |
|
|
| seconds. |
|
|
|
|
|
|
16 | Wash 2 3/27 | 0:30 | The basket should rotate forward 3 seconds, | Refer to the “No Motor Operation (With or |
| (80°F) |
| pause for 27 seconds, rotate in reverse for 3 | With No AC Drive Fault” flowchart. |
|
|
| seconds, pause for 27 seconds, etc. |
|
|
|
|
|
|
17 | Wash 3, no | 0:30 | The basket should not rotate for 30 seconds. | If the basket does rotate, check the |
| agitation (80°F) |
|
| program. |
|
|
|
|
|
18 | Wash 4 10/3 | 0:30 | The basket should rotate forward 10 seconds, | Refer to the “No Motor Operation (With or |
| (80°F) |
| pause for 3 seconds, rotate in reverse for 10 | With No AC Drive Fault” flowchart. |
|
|
| seconds, pause for 3 seconds, etc. |
|
|
|
|
|
|
19 | Wash 1, no | 0:30 | The basket should rotate forward for 30 | Refer to the “No Motor Operation (With or |
| reverse (80°F) |
| seconds without pausing. | With No AC Drive Fault” flowchart. |
|
|
|
|
|
20 | Drain 1 | 1:00 | The machine should drain within 1 minute | Refer to the “Empty Alarm Analysis” |
|
|
| and, when it does, a buzzer will sound. | flowchart. |
|
|
|
|
|
Table 1
9001900 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 67 |