Page
Troubleshooting
1. WE-8CONTROL HAS NO VISIBLE DISPLAY (P AND N-VOLTAGEMODELS)
Please refer to the following 2 pages for wiring diagram information
WE-8Control Has No Visible Display (P and N-VoltageModels) (Sheet 1 of 2)
NOTE: Refer to the wiring diagram supplied with your machine
WE-8Control Has No Visible Display (P and N-VoltageModels) (Sheet 2 of 2)
2. WE-8CONTROL HAS NO VISIBLE DISPLAY (Q AND X-VOLTAGEMODELS)
Page
WE-8Control Has No Visible Display (Q and X-VoltageModels) (Sheet 1 of 2)
WE-8Control Has No Visible Display (Q and X-VoltageModels) (Sheet 2 of 2)
3. NO FILL ANALYSIS
Page
No Fill Analysis (Sheet 1 of 2)
No Fill Analysis (Sheet 2 of 2)
4. WATER RUNS CONTINUOUSLY INTO THE WASHER-EXTRACTOR
Page
Water Runs Continuously into the Washer-Extractor(Sheet 1 of 2)
Water Runs Continuously into the Washer-Extractor(Sheet 2 of 2)
5. DOOR LOCK SWITCH ANALYSIS: DISPLAY SHOWS “DOOR ERROR”
Page
Door Lock Switch Analysis: Display Shows “Door Error” (Sheet 1 of 2)
Door Lock Switch Analysis: Display Shows “Door Error” (Sheet 2 of 2)
6. DOOR LOCK SWITCH ANALYSIS: DISPLAY READS “PLEASE CLOSE DOOR”
Page
Door Lock Switch Analysis: Display Reads “Please Close Door” (Sheet 1 of 2)
Door Lock Switch Analysis: Display Reads “Please Close Door” (Sheet 2 of 2)
7. DOOR LOCK SWITCH ANALYSIS: “DOOR WON’T UNLOCK”
Page
Door Lock Switch Analysis: “Door Won’t Unlock” (Sheet 1 of 2)
Door Lock Switch Analysis: “Door Won’t Unlock” (Sheet 2 of 2)
8. NO OUTPUT VOLTAGE TO COMPONENTS
Page
No Output Voltage to Components (Sheet 1 of 2)
No Output Voltage to Components (Sheet 2 of 2)
9. NO MOTOR OPERATION WITH NO AC DRIVE FAULT
Page
No Motor Operation With No AC Drive Fault (Sheet 1 of 2)
No Motor Operation With No AC Drive Fault (Sheet 2 of 2)
10. NO MOTOR OPERATION WITH AC DRIVE FAULT
No Motor Operation With AC Drive Fault
Operation
Indication
Name
Description and NOTES
No Motor Operation With AC Drive Fault(continued)
Indication Name
11.THE MOTOR IS RUNNING, BUT AT AN ABNORMAL SPEED Preliminary Checks:
Secondary Checks:
Calibration of the Machine
12. NO SPIN
13. MACHINE DID NOT FILL ALARM ANALYSIS
Page
Machine Did Not Fill Alarm Analysis (Sheet 1 of 2)
Machine Did Not Fill Alarm Analysis (Sheet 2 of 2)
14. EMPTY ALARM ANALYSIS
Page
Empty Alarm Analysis (Sheet 1 of 2)
Empty Alarm Analysis (Sheet 2 of 2)
15.AUTOMATIC SUPPLY DISPENSER ANALYSIS Run Program
Cycle
Supply Setup
Supply
Function
Page
16. NO KEYPAD BOARD FUNCTIONS
17.EXCESSIVE CYCLE TIME
b.Drain Time:
NOTE: Any drain step should not exceed 30-40seconds
c.Unnecessary Programming Steps:
18.EXCESSIVE VIBRATION AND/OR NOISE DURING SPIN
a.Improper Loading:
b.Improper Installation:
c.Faulty Trunnion Bearings:
Service Procedures
21.COMPUTER BOARD REMOVAL AND INSTALLATION
Cycle 39 — Test Program
Cycle 39 — Test Program (continued)
22.KEYMODE SWITCH REMOVAL AND INSTALLATION
23.AC DRIVE SWITCH REMOVAL AND INSTALLATION
NOTE: To check the RPM’s, press the “Display Temp” keypad
18, 25, 35, 55 and 75-PoundCapacity Machines
100and 135-PoundCapacity Machines
165-PoundCapacity Machines
24.REAR PANEL REMOVAL AND REPLACEMENT
25.SIDE PANEL REMOVAL AND INSTALLATION
26.DRIVE BELT REMOVAL AND REPLACEMENT
DRIVE BELT RE-TENSIONING
27.WATER VALVE REMOVAL AND REPLACEMENT
29.DOOR GASKET REMOVAL AND REPLACEMENT
REMOVAL Refer to Figure
MOTOR REMOVAL AND REPLACEMENT (100, 135 and