Section 3 Troubleshooting
3. NO FILL ANALYSIS
|
|
| Is |
|
|
|
| there water | NO |
|
|
| coming in through | |
|
|
|
| |
| Replace the valve’s solenoid if |
| the water supply |
|
| available. If the solenoid isn’t |
| lines? |
|
| available, replace the entire |
|
|
|
| valve. |
|
|
|
|
|
| YES |
|
| NO |
| 1 |
|
| Is there |
| Is there voltage |
|
|
| (220 Volts) between the |
| |
| magnetism within | YES |
| |
| two wires of the |
| ||
| the center |
| ||
|
| water valve that |
| |
| walls of the |
|
| |
|
| has been |
| |
| valve |
|
| |
|
| programmed to turn |
| |
| solenoid? |
|
| |
|
| on? |
| |
|
|
|
| |
| YES |
|
|
|
|
|
| NO |
|
| Replace or repair the |
|
|
|
| mechanical parts of the valve |
| 2 |
|
| with a repair kit if available. If |
|
| |
|
|
|
| |
| a repair kit isn’t available, |
| Is |
|
| replace the entire valve. |
|
| |
|
| there voltage |
| |
|
|
|
| |
|
|
|
| |
|
|
| (220 Volts) between |
|
|
|
| the wire from the main |
|
|
|
| board harness on the water |
|
|
|
| valve that has been programmed | |
|
|
| to turn on? |
|
|
|
| The red wire is the hot fill, |
|
|
|
| the gray wire is the cold fill |
|
|
|
| and the blue wire |
|
|
|
| is the neutral. |
|
YES
Check the wiring between the main board and the water valve that has been programmed to turn on. Repair or replace the wiring as needed.
Note: There may be a modular connector between the wire and the main board.
Check the main water valve
Assuming that all checks were done correctly, replace the
NO main board or contact Alliance Laundry Systems’ customer service department to verify that all checks have been done correctly.