Section 3 Troubleshooting

3. NO FILL ANALYSIS

 

 

 

Is

 

 

 

 

there water

NO

 

 

 

coming in through

 

 

 

 

 

Replace the valve’s solenoid if

 

the water supply

 

 

available. If the solenoid isn’t

 

lines?

 

 

available, replace the entire

 

 

 

 

valve.

 

 

 

 

 

 

YES

 

 

NO

 

1

 

 

Is there

 

Is there voltage

 

 

 

(220 Volts) between the

 

 

magnetism within

YES

 

 

two wires of the

 

 

the center

 

 

 

water valve that

 

 

walls of the

 

 

 

 

has been

 

 

valve

 

 

 

 

programmed to turn

 

 

solenoid?

 

 

 

 

on?

 

 

 

 

 

 

YES

 

 

 

 

 

 

NO

 

 

Replace or repair the

 

 

 

 

mechanical parts of the valve

 

2

 

 

with a repair kit if available. If

 

 

 

 

 

 

 

a repair kit isn’t available,

 

Is

 

 

replace the entire valve.

 

 

 

 

there voltage

 

 

 

 

 

 

 

 

 

 

 

 

(220 Volts) between

 

 

 

 

the wire from the main

 

 

 

 

board harness on the water

 

 

 

 

valve that has been programmed

 

 

 

to turn on?

 

 

 

 

The red wire is the hot fill,

 

 

 

 

the gray wire is the cold fill

 

 

 

 

and the blue wire

 

 

 

 

is the neutral.

 

YES

Check the wiring between the main board and the water valve that has been programmed to turn on. Repair or replace the wiring as needed.

Note: There may be a modular connector between the wire and the main board.

Check the main water valve shut-offs to make sure that they are turned on. Check inside of the water hoses and in-line screens for any blockages.

Assuming that all checks were done correctly, replace the

NO main board or contact Alliance Laundry Systems’ customer service department to verify that all checks have been done correctly.