Section 3 Troubleshooting
14. EMPTY ALARM ANALYSISThe display reads “DID NOT
EMPTY.”
Is
there voltage
(220 Volts) at the
drain valve?
NO
1
Is
there voltage
(220 Volts) between the blue and gray wires going into the drain connection on the main board?
YES
Is
there continuity
from the drain
connection on the main board to the drain valve harness?
NO
Replace the drain harness.
Check the drain valve and drain plumbing for blockage.
NO
Replace the main board.
YES
Replace the main board.
CFD1991S